Abstract
This study examines the impact attenuation performance of airbags of different shapes, thicknesses, and internal pressures to assess their effectiveness in hip protection. Three distinct airbag shapes are examined and analyzed under different thicknesses and pressures, with experimental tests conducted to assess the relationships between thickness, pressure, stiffness, and impact absorption efficiency. The results reveal that increasing the thickness of the airbag significantly reduces the peak impact force, while higher internal pressure increases stiffness but does not always lead to improveδ impact attenuation. Among the three airbag shapes, the torus-shaped airbag demonstrates the lowest peak impact force and the highest impact absorption efficiency. Additionally, airbags maintained at atmospheric pressure (0 psi) exhibit the greatest impact absorption efficiency, followed by those at 3 psi and 6 psi, respectively. Comparing existing studies on traditional hip protectors, the results indicate that airbags provide a superior reduction in impact force. Unlike conventional hip protectors, which primarily rely on direct force absorption, the torus airbag employs an off-loading mechanism to dissipate impact energy, thereby enhancing its protective performance. These findings suggest that airbag-based protective systems could serve as an innovative solution for reducing fall-related injuries.Keywords
This publication has 32 references indexed in Scilit:
- Ballistic response of an airbag with parallel ribs under spherical projectile impactComposite Structures, 2024
- Biomechanical testing of hip protectors following the Canadian Standards Association express documentOsteoporosis International, 2019
- Impact Attenuation of the Soft Pads and the Wearable Airbag for the Hip Protection in the ElderlyInternational Journal of Precision Engineering and Manufacturing, 2019
- Development of a Wearable Airbag for Preventing Fall Related Injuries2011
- The effect of positioning on the biomechanical performance of soft shell hip protectorsJournal of Biomechanics, 2010
- Hip protectors: recommendations for biomechanical testing—an international consensus statement (part I)Osteoporosis International, 2009
- Hip protectors: recommendations for conducting clinical trials—an international consensus statement (part II)Osteoporosis International, 2009
- The association between osteoporotic fractures and health-related quality of life as measured by the Health Utilities Index in the Canadian Multicentre Osteoporosis Study (CaMos)Osteoporosis International, 2003
- Survival and Potential Years of Life Lost After Hip Fracture in Men and Age-matched WomenOsteoporosis International, 2002
- Long-Term Risk of Osteoporotic Fracture in MalmöOsteoporosis International, 2000