The dose response of normoxic polymer gel dosimeters measured using X-ray CT
Authors:
- B HillBHB Hill
- A VenningAVA Venning
- C BaldockCBC Baldock
- 1 July 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 78 (931) , 623-630
Abstract
X-ray CT was used to determine the dose response of normoxic polymer gel dosimeters. Normoxic polymer gel dosimeters were manufactured and irradiated up to 150 Gy. Up to 50 CT images were acquired on a Toshiba Aquilion Multislice CT scanner using protocols for 80 kV and 135 kV to determine dose response. HU-dose sensitivity, the linear regression of data for the HU versus dose for the linear part of the curve up to 60 Gy was 0.38±0.07 HU Gy−1 for 135 kV and 0.37±0.01 HU Gy−1 for 80 kV. Dose resolution was found to be < 1.3 Gy for an absorbed dose range up to 70 Gy for 135 kV, similar to that measured previously for polyacrylamide gel (PAG). Although the HU-dose sensitivity was lower than that previously measured for PAG gel dosimeters it had a greater range of absorbed dose indicating that normoxic polymer gel dosimeters have potential in CT gel dosimetry.Keywords
This publication has 29 references indexed in Scilit:
- Use of normoxic polymer gel dosimeters for measuring diagnostic doses on CT scannersJournal of Physics: Conference Series, 2004
- Image filtering for improved dose resolution in CT polymer gel dosimetryMedical Physics, 2003
- An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomographyPhysics in Medicine & Biology, 2001
- High resolution gel‐dosimetry by optical‐CT and MR scanningMedical Physics, 2001
- Spiral interpolation algorithm for multislice spiral CT. I. TheoryIEEE Transactions on Medical Imaging, 2000
- Spiral interpolation algorithms for multislice spiral CT. II. Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice systemIEEE Transactions on Medical Imaging, 2000
- Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gelPhysics in Medicine & Biology, 1996
- Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeterPhysics in Medicine & Biology, 1994
- NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRIMagnetic Resonance Imaging, 1993
- The Use of Contrast-Detail-Dose Evaluation of Image Quality in a Computed Tomographic ScannerJournal of Computer Assisted Tomography, 1979