Comparison of visually estimated blood loss with direct hemoglobin measurement in multilevel spine surgery
- 26 February 2013
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 53 (11) , 2790-2794
Abstract
Background: Estimates of blood loss in the operating room are typically performed as a visual assessment by providers, despite multiple studies showing this to be inaccurate. Use of a less subjective measurement of blood loss such as direct measurement of the hemoglobin (Hb) mass lost from the surgical field may better quantify surgical bleeding. The objective of this investigation was to compare anesthesiologist estimates of intraoperative blood loss with measured Hb loss.Study Design and Methods: Sixty patients undergoing posterior spine surgery were enrolled in a prospective, randomized trial comparing intraoperative blood loss using unipolar cautery alone or with use of a bipolar tissue sealant device. Hb concentration and fluid volume were measured from all surgical sponges, suction canisters, and the cell salvage device. Using the volume and concentration of Hb from each solution allowed calculation of Hb mass, which was converted into volume of blood lost and compared with estimates of blood loss documented by the anesthesia team. A single‐sample t test of no difference was used to compare estimated with measured blood loss.Results: Mean estimated blood loss exceeded measured blood loss by 246 mL (860 mL vs. 614 mL, p < 0.0001).Conclusion: Estimated blood loss exceeded measured blood loss by 40% on average. The likely etiology of this discrepancy relates to the inability to visually determine Hb concentration of sanguineous solutions in suction canisters and surgical sponges. Ramifications of excessive bleeding estimates include unnecessary transfusion and overadministration of intravenous fluids, both of which may have deleterious effects.Keywords
This publication has 17 references indexed in Scilit:
- Blood Loss Estimation During Fronto-Orbital AdvancementJournal of Craniofacial Surgery, 2012
- Bipolar tissue sealant device decreases hemoglobin loss in multilevel spine surgeryTransfusion, 2012
- Comparison of the Accuracy of Noninvasive Hemoglobin Monitoring by Spectrophotometry (SpHb) and HemoCue® with Automated Laboratory Hemoglobin MeasurementAnesthesiology, 2011
- Proper Estimation of Blood Loss on Scene of Trauma: Tool or Tale?Journal of Trauma: Injury, Infection & Critical Care, 2010
- Measurement of Blood Loss: Review of the LiteratureJournal of Midwifery & Women's Health, 2010
- Clinical consequences of red cell storage in the critically illTransfusion, 2006
- Estimating Blood Loss: Can Teaching Significantly Improve Visual Estimation?Obstetrics & Gynecology, 2004
- Blood Transfusion, Independent of Shock Severity, Is Associated with Worse Outcome in Trauma2003
- Treatment for dysphagia in chronic muscle disease2002
- A Comparison Between Visual Estimation and Laboratory Detennination of Blood Loss During the Third Stage of LabourAustralian and New Zealand Journal of Obstetrics and Gynaecology, 1996