SF6 fault decomposition feature component extraction and triangle fault diagnosis method
Authors:
- 25 March 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 27 (2) , 581-589
Abstract
How to use SF 6 decomposition feature component information to judge the form and degree of gas-insulated equipment (GIE) field discharge and overthermal faults quickly is a problem that remains unresolved. Based on the existing experimental data on SF 6 typical fault decomposition, this study considers the SF 6 decomposition mechanism under typical faults and uses the maximum correlation minimum redundancy criterion to filter out three decomposition feature components characterizing GIE typical fault attributes: SOF 2 +SO 2 , CF 4 , and SO 2 F 2 . The weight of extracted feature components is optimized by the "area equivalence principle," and the triangle fault diagnosis method of the SF 6 decomposition component that is suitable for the rapid diagnosis of a GIE field is constructed. The diagnosis method is comprehensively tested using faulty data in different conditions, and the comprehensive recognition rate of lab tests reaches 96.2%. Results show that the constructed triangle fault diagnosis method of the SF 6 decomposition component can diagnose the internal fault nature of a GIE and identify the types of insulation defects that induce partial discharge faults. Moreover, the constructed method in this research is simple, effective, and suitable for field maintenance and online intelligent monitoring of GIE.Keywords
This publication has 19 references indexed in Scilit:
- Decomposition characteristics of SF6under three typical defects and the diagnostic application of triangle methodIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Study on the influence mechanism of trace H2O on SF6 thermal decomposition characteristic componentsIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Influence regularity of trace O6 on SF6 decomposition characteristics and its mathematical amendment under partial dischargeIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Correlation analysis between formation process of SF6 decomposed components and partial discharge qualitiesIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- Partial discharge recognition through an analysis of SF6 decomposition products part 2: feature extraction and decision tree-based pattern recognitionIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Partial discharge recognition through an analysis of SF6 decomposition products part 1: decomposition characteristics of SF6 under four different partial dischargesIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Detecting Novel Associations in Large Data SetsScience, 2011
- The duval triangle for load tap changers, non-mineral oils and low temperature faults in transformersIEEE Electrical Insulation Magazine, 2008
- Feature selection based on mutual information criteria of max-dependency, max-relevance, and min-redundancyIEEE Transactions on Pattern Analysis and Machine Intelligence, 2005
- Activity of moving metallic particles in prebreakdown state in GISIEEE Transactions on Dielectrics and Electrical Insulation, 1997