Perimetry of the Central Visual Field Using a Head-Mounted Open-Source Perimeter in Patients with Inherited Retinal Diseases
Preprint
- 8 January 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Head-mounted (“virtual reality”) perimeters (HMPs), based on standard consumer electronic hardware, are a cheaper alternative to standard automated perimetry. They have not been validated in patients with inherited retinal disease (IRDs), yet. We evaluated the Iowa-HMP in a first pilot study. It consists of a legacy smartphone, a headset, and freely available, open-source software. We used the 10-2 grid, the ZEST algorithm, and a background of 10 cd/m^2 to measure central visual fields in one normal subject, and in patients with occult macular dystrophy (n = 2), Stargardt’s disease (n=3) and retinitis pigmentosa (n = 6). Results were compared with those from an Octopus 900 perimeter. The typical patterns of visual field loss were clearly discernible, but head-mounted perimeters generally have a limited dynamic range. Within the dynamic range of the Iowa-HMP (14 to 30 dB Octopus sensitivity), the Limits of Agreement (Bland-Altman) were ±7.5 dB. The Iowa-HMP had a diagnostic sensitivity of 0.67 for detecting locations with low perimetric sensitivity (< 14 dB in the Octopus perimetry) with a diagnostic specificity of 0.95. Although the Iowa-HMP cannot be directly compared to standard perimetry in IRDs, open software greatly facilitates research in this area.Keywords
All Related Versions
This publication has 39 references indexed in Scilit:
- Standard automated perimetry for glaucoma and diseases of the retina and visual pathways: Current and future perspectivesProgress in Retinal and Eye Research, 2024
- Pattern electroretinogram, blue-yellow visual evoked potentials and the risk of developing visual field defects in glaucoma suspects: a longitudinal “survival” analysis with a very long follow-upGraefe's Archive for Clinical and Experimental Ophthalmology, 2024
- Fundus-controlled perimetry (microperimetry): Application as outcome measure in clinical trialsProgress in Retinal and Eye Research, 2021
- Six-month Longitudinal Comparison of a Portable Tablet Perimeter With the Humphrey Field AnalyzerAmerican Journal of Ophthalmology, 2018
- Can Home Monitoring Allow Earlier Detection of Rapid Visual Field Progression in Glaucoma?Ophthalmology, 2017
- Recommendations on Screening for Chloroquine and Hydroxychloroquine Retinopathy (2016 Revision)Ophthalmology, 2016
- The Effective Dynamic Ranges of Standard Automated Perimetry Sizes III and V and Motion and Matrix PerimetryArchives of Ophthalmology (1950), 2010
- Quantifying rod photoreceptor-mediated vision in retinal degenerations: dark-adapted thresholds as outcome measuresExperimental Eye Research, 2005
- Comparison of Quantitative Testing With the Octopus, Humphrey, and Tübingen PerimetersAmerican Journal of Ophthalmology, 1986
- Problems related to the design of automatic perimetersDocumenta Ophthalmologica, 1979