Pulse Transit Time Based on Piezoelectric Technique at the Radial Artery
- 16 May 2006
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 20 (3) , 185-192
Abstract
Objectives. Pulse transit time (PTT) has shown its potential in relevant cardiovascular and cardiorespiratory studies. However, the use of photoplethysmography (PPG) in PTT measurement can be limited in events of poor peripheral perfusion. Uninterrupted PTT monitoring may also not be achievable when less cooperative patients distribute the PPG probe due to its prominent light source. Hence, there is a need for an alternative method to measure PTT in such incidents. Methods. In this study, the piezoelectric (PIEZO) technique to detect pulsations from a human wrist above the radial artery to estimate PTT is presented. 17 healthy adults (11 male; age range of 21–33 years) were recruited to compare PTT and heart rate (HR) differences between the PPG and PIEZO methods. These time-related derivations were made with respect to an electrocardiogram (ECG). Results. The timing consistency of the PIEZO transducer shows significant correlations (p < 0.01) to those derived from the ECG and a pulse oximeter. Particularly, there is a high level of agreement of < 1beat per minute (bpm) difference in HR estimates observed when compared to the two commercial devices in the respective Bland-Altman plots. Comparison of PTT obtained from the PIEZO transducer against the PPG signal shows constantly lower values due to the shorter path length it requires to propagate. A regression equation was formulated to relate the PTT values acquired from both these signals. Conclusions. Preliminary findings herein suggest that the PIEZO technique can be useful as an alternative for PTT monitoring. This shows promise to be more accommodating for less cooperative patients or those with insufficient peripheral perfusion.Keywords
This publication has 16 references indexed in Scilit:
- Guidelines for the cold pressor task as an experimental pain stimulus for use with childrenThe Journal of Pain, 2005
- An ultrasound-based method for determining pulse wave velocity in superficial arteriesJournal of Biomechanics, 2004
- Effects of passive smoking on blood pressure and aortic pressure waveform in healthy young adults – influence of genderBritish Journal of Clinical Pharmacology, 2003
- Pulse Transit Time as a Measure of Arousal and Respiratory Effort in Children with Sleep-Disordered BreathingPediatric Research, 2003
- Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toesJournal of Human Hypertension, 2002
- Arterial distensibility in children and teenagers: normal evolution and the effect of childhood vasculitisArchives of Disease in Childhood, 2002
- Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patientsPhysiological Measurement, 2002
- Pulse transit time: an appraisal of potential clinical applicationsThorax, 1999
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Effects of aging on changing arterial compliance and left ventricular load in a northern Chinese urban community.Circulation, 1983