Study of the metrological characteristics of the hydrostatic pressure sensor
- 16 September 2019
- journal article
- research article
- Published by Emerald Publishing in Sensor Review
- Vol. 39 (5) , 665-669
Abstract
Purpose: The purpose of this paper is to develop a digital hydrostatic pressure sensor with the required metrological and operational characteristics. The developed sensor is designed to control hydrostatic pressure in wells during various geophysical works and studies.Design/methodology/approach: To obtain the required metrological and operational characteristics of the sensor, a method was developed and applied to reduce the measurement error based on the calibration algorithm and the sensor model.Findings: By using the developed calibration algorithm and the mathematical model of the sensor, it was possible to compensate for the measurement errors of the hydrostatic pressure sensor.Originality/value: In the course of this research, tests of the developed sensor were carried and the maximum/minimum of measurement result errors was determined.Keywords
This publication has 4 references indexed in Scilit:
- Fiber optic sensor for hydrostatic pressure and temperature measurement in riverbanks monitoringOptics & Laser Technology, 2016
- Stability monitoring of rainfall-induced deep landslides through pore pressure profile measurementsSoils and Foundations, 2012
- Hydrostatic pressure sensor based on carbon sphere – polyvinyl alcohol compositesOrganic Electronics, 2010
- Pressure Sensors: Selection and ApplicationSensor Review, 2002