Ocular biometric differences between long and not long-axial length eyes
Preprint
- 17 August 2023
- preprint
- Published by Springer Nature in Research Square
Abstract
This retrospective cross-sectional study aimed to measure parameters of preoperative cataract patients and examines the correlations between each parameter. The 210 subjects had their ocular axial lengths measured with OA-2000. The endpoints were ocular axial length (AL), central corneal thickness (CCT), average corneal radii (CR), white-to-white(WTW), anterior chamber depth(ACD), and lens thickness(LT). AL was mainly employed for each person. Each parameter was analyzed for correlations in a round-robin manner. Regression analyses were performed on parameters correlated with AL. The parameters correlated with AL were CR (r = 0.33, p < 0.0001), WTW (r = 0.29, p < 0.0001), ACD (r = 0.59, p < 0.0001), and LT (r = −0.30, p < 0.0001). These parameters affected AL in all single regression equations (CR (P < 0.0001), WTW (P = 0.0002), ACD (P < 0.0001), LT (P = 0.0001)). In multiple regression analyses, CR, ACD, and LT might affect AL (CR (P = 0.0002), ACD (P < 0.0001), LT (P = 0.018)). LT tended to be thinner as AL increased, while CR, WTW, and ACD tended to increase. This information will be useful in developing strategies for ophthalmic surgery.Keywords
All Related Versions
This publication has 27 references indexed in Scilit:
- Ocular Axial Length and Its Associations in Chinese: The Beijing Eye StudyPLOS ONE, 2012
- Ocular Biometry in an Urban Indian Population: The Singapore Indian Eye Study (SINDI)Investigative Ophthalmology & Visual Science, 2011
- Ocular Axial Length and Its Associations in an Adult Population of Central Rural India: The Central India Eye and Medical StudyOphthalmology, 2010
- Distribution of Axial Length and Ocular Biometry Measured Using Partial Coherence Laser Interferometry (IOL Master) in an Older White PopulationOphthalmology, 2010
- Distribution and Determinants of Ocular Biometric Parameters in an Asian Population: The Singapore Malay Eye StudyInvestigative Ophthalmology & Visual Science, 2010
- Relation between Axial Length and Ocular ParametersOphthalmologica, 2009
- Lens thickness of Indian eyes: impact of isolated lens opacity, age, axial length, and influence on anterior chamber depthEye, 2008
- Variability of axial length, anterior chamber depth, and lens thickness in the cataractous eyeJournal of Cataract & Refractive Surgery, 2008
- Central Corneal Thickness is not Related to Anterior Scleral Thickness or Axial LengthJournal of Glaucoma, 2006
- Form deprivation myopia: elastic properties of scleraOphthalmic and Physiological Optics, 1995