Study on existing reinforced concrete buildings seismic vulnerability after retrofitting
Open Access
- 1 January 2023
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2759 (1)
Abstract
The present study focusses on retrofitting of the seismically deficient gravity designed existing RC buildings. Four RC buildings which is existing in India were taken for this analysis. All the structures are subjected to Non-linear Static Pushover(PO) and Dynamic Time History(TH) Analysis using SAP 2000 to check the capacity of structures under seismic loads. The plastic hinges are assigned as per the guidelines of FEMA 356 in. Pushover analysis. Elcentro Ground motion is used for dynamic analysis. The comparison is made between Pushover and Time History Analysis to check how closely the Pushover analysis estimates the dynamic response of the structure. The analysis showed damages in all the buildings with formation of hinges above Collapse Prevention (CP) level. Also, the interstorey drifts of all the buildings exceeded the drift limit as per IS1893. Hence, each building is retrofitted with different suiTABLE retrofitting techniques. Further, the retrofitted buildings are subjected to the Non-linear Static Pushover and Dynamic Time History Analysis and compared with the unretrofitted buildings to check the resilience of the structure under seismic loads.Keywords
This publication has 10 references indexed in Scilit:
- Performance Evaluation of 9 Storey RC Building Located in North GoaProcedia Engineering, 2017
- Nonlinear Seismic Analysis of Masonry Infill RC Buildings with Eccentric Bracings at Soft Storey LevelProcedia Engineering, 2016
- Comparative study of the seismic response of RC framed buildings retrofitted using modern techniquesEarthquakes and Structures, 2015
- Seismic Assessment of RC Building According to ATC 40, FEMA 356 and FEMA 440Arabian Journal for Science and Engineering, 2014
- An innovative methodology for seismic retrofitting of existing RC buildings by metal shear panelsEarthquake Engineering & Structural Dynamics, 2008
- Seismic Assessment of Concentrically Braced Steel Frames with Shape Memory Alloy BracesJournal of Structural Engineering, 2007
- Seismic retrofit of a reinforced concrete flat-slab structure: Part I — seismic performance evaluationEngineering Structures, 2007
- Evaluation of retrofit strategies for reinforced concrete columns:Engineering Structures, 2000
- Seismic Demand Evaluation for a 4-Story Steel Frame Structure Damaged in the Northridge EarthquakeThe Structural Design of Tall Buildings, 1996