Methodological considerations for analyzing trabecular architecture: an example from the primate hand
Open Access
- 26 October 2010
- journal article
- research article
- Published by Wiley in Journal of Anatomy
- Vol. 218 (2) , 209-225
Abstract
Micro-computed tomographic analyses of trabecular bone architecture have been used to clarify the link between positional behavior and skeletal anatomy in primates. However, there are methodological decisions associated with quantifying and comparing trabecular anatomy across taxa that vary greatly in body size and morphology that can affect characterizations of trabecular architecture, such as choice of the volume of interest (VOI) size and location. The potential effects of these decisions may be amplified in small, irregular-shaped bones of the hands and feet that have more complex external morphology and more heterogeneous trabecular structure compared to, for example, the spherical epiphysis of the femoral head. In this study we investigate the effects of changes in VOI size and location on standard trabecular parameters in two bones of the hand, the capitate and third metacarpal, in a diverse sample of nonhuman primates that vary greatly in morphology, body mass and positional behavior. Results demonstrate that changes in VOI location and, to a lesser extent, changes in VOI size had a dramatic affect on many trabecular parameters, especially trabecular connectivity and structure (rods vs. plates), degree of anisotropy, and the primary orientation of the trabeculae. Although previous research has shown that some trabecular parameters are susceptible to slight variations in methodology (e.g. VOI location, scan resolution), this study provides a quantification of these effects in hand bones of a diverse sample of primates. An a priori understanding of the inherent biases created by the choice of VOI size and particularly location is critical to robust trabecular analysis and functional interpretation, especially in small bones with complex arthroses.Keywords
This publication has 43 references indexed in Scilit:
- Scaling VOI size in 3D μCT studies of trabecular bone: A test of the over‐sampling hypothesisAmerican Journal of Physical Anthropology, 2010
- Metacarpal trabecular architecture variation in the chimpanzee (Pan troglodytes): Evidence for locomotion and tool‐use?American Journal of Physical Anthropology, 2010
- A new high‐resolution computed tomography (CT) segmentation method for trabecular bone architectural analysisAmerican Journal of Physical Anthropology, 2009
- Locomotion-related Femoral Trabecular Architectures in Primates — High Resolution Computed Tomographies and Their Implications for Estimations of Locomotor Preferences of Fossil Primates2009
- A three‐dimensional microcomputed tomographic study of site‐specific variation in trabecular microarchitecture in the human second metacarpalJournal of Anatomy, 2008
- Resolution Dependence of the Non-metric Trabecular Structure IndicesBone, 2008
- A Population-Based Assessment of Rates of Bone Loss at Multiple Skeletal Sites: Evidence for Substantial Trabecular Bone Loss in Young Adult Women and MenJournal of Bone and Mineral Research, 2008
- Interrelationship of trabecular mechanical and microstructural properties in sheep trabecular boneJournal of Biomechanics, 2005
- On Wolff's law of trabecular architectureJournal of Biomechanics, 1992
- On the dependence of the elasticity and strength of cancellous bone on apparent densityJournal of Biomechanics, 1988