Coronary Artery Anomalies and Variants: Technical Feasibility of Assessment with Coronary MR Angiography at 3 T
Authors:
- Ahmed M. GharibAGAhmed M. Gharib
- Vincent B. HoVHVincent B. Ho
- Douglas R. RosingDRDouglas R. Rosing
- Daniel A. HerzkaDHDaniel A. Herzka
- Matthias StuberMSMatthias Stuber
- Andrew E. AraiAAAndrew E. Arai
- Roderic I. PettigrewRPRoderic I. Pettigrew
- 1 April 2008
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 247 (1) , 220-227
Abstract
The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18-62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically-gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20 degrees flip angle; 1 x 1 x 2-mm acquired voxel size) lasted 10-12 minutes. Mean examination time was 41 minutes +/- 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV.Keywords
This publication has 43 references indexed in Scilit:
- B1‐insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 TMagnetic Resonance in Medicine, 2006
- Detection and assessment of coronary artery anomalies by three-dimensional magnetic resonance coronary angiographyInternational Journal of Cardiology, 2005
- Evaluation of Balanced Steady-State Free Precession (TrueFISP) and K-space Segmented Gradient Echo Sequences for 3D Coronary MR Angiography with Navigator Gating at 3 TeslaRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995
- Anomalous coronary arteries: location, degree of atherosclerosis and effect on survival—a report from the coronary artery surgery studyJACC, 1989
- Origin of the right coronary artery from the left sinus of Valsalva and its functional consequences: Analysis of 10 necropsy patientsThe American Journal of Cardiology, 1982
- Aberrant coronary artery origin from the aorta. Report of 18 patients, review of literature and delineation of natural history and management.Circulation, 1979
- Sudden Death as a Complication of Anomalous Left Coronary Origin From the Anterior Sinus of ValsalvaCirculation, 1974
- Anomalies of the Coronary Arteries and their Clinical SignificanceCirculation, 1956