Autologous resurfacing
Authors:
- 3 October 2014
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 78 (1) , 40-51
Abstract
Background: There is a discrepancy between the interest in joint‐reconstructions and the current knowledge about the healing‐processes involved. Major reconstructions are performed with osteosynthesized allografts and fresh allografts for cartilage. Objectives: The main question to be answered is: what do we know about metaphyseal and epiphyseal cancellous bone healing, contact healing of the subchondral bone and its influence on cartilage healing? Can we achieve healing of all four compartments in contact? Purpose: The purpose is to systematically investigate through animal testing the healing processes of metaphyseal and epiphyseal bone, including the subchondral bone and the healing of cartilage of press‐fit‐inserted grafts, considering nondemineralized high‐resolution histology. Material and Methods: Primary cancellous‐bone healing of osteosynthesized hemi‐osteotomies was studied in 13 canine tibial heads, the contact healing was investigated in 7 dogs and 18 giant‐rabbits comparing contact‐healing of press‐fit‐inserted autologs cylindrical grafts with empty defects applying the wet‐grinding diamond‐technology. Bench‐experiments on the epiphyseal bones of swine including pullout‐tests of cylindrical grafts formed the basis for validation of that press‐fit diamond technology. Results: Primary metaphyseal and epiphyseal contact healing, including hyaline cartilage, was found in all compartments of the meta‐and epiphysis in the precisely performed experiments. The press‐fit principle, which employs cylindrical grafts and diamond instrumentation featuring a difference of 15/100 mm between graft and recipient bed, achieved high loads between 73.48 and 178.95 N (mean value 118.16 and standard deviation 32.79) in the pullout tests. Conclusion: Autologous press‐fit grafting with alignment of the bony baseplate using wet‐grinding precision has attained promising histo‐morphological results. Microsc. Res. Tech., 78:40–51, 2015.Keywords
This publication has 30 references indexed in Scilit:
- Real-time measurement of solute transport within the lacunar-canalicular system of mechanically loaded bone: Direct evidence for load-induced fluid flowJournal of Bone and Mineral Research, 2010
- Fresh Osteochondral Allografts for Posttraumatic Knee Defects: Long-term FollowupClinical Orthopaedics and Related Research, 2008
- Histological examination of drill sites in bovine rib bone after grinding in vitro with eight different devicesBritish Journal of Oral and Maxillofacial Surgery, 2007
- Mosaicplasty for the Treatment of Articular Defects of the Knee and AnkleClinical Orthopaedics and Related Research, 2001
- Osteochondral autologous graft transferOperative Techniques in Sports Medicine, 2000
- Treatment of Deep Cartilage Defects in the Knee with Autologous Chondrocyte TransplantationNew England Journal of Medicine, 1994
- Finite element studies of some juxtarticular stress changes due to localized subchondral stiffeningJournal of Biomechanics, 1984
- Reconstruction of Skeletal Deficits at the KneeClinical Orthopaedics and Related Research, 1983
- Transport mechanism operating between blood supply and osteocytes in long bonesNature, 1977
- The response of joints to impact loading — II In vivo behavior of subchondral boneJournal of Biomechanics, 1972