Tibial component rotation in total knee arthroplasty
Open Access
- 16 February 2016
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-6
Abstract
Both the range of motion (ROM) technique and the tibial tubercle landmark (TTL) technique are frequently used to align the tibial component into proper rotational position during total knee arthroplasty (TKA). The aim of the study was to assess the intra-operative differences in tibial rotation position during computer-navigated primary TKA using either the TTL or ROM techniques. The ROM technique was hypothesized to be a repeatable method and to produce different tibial rotation positions compared to the TTL technique. A prospective, observational study was performed to evaluate the antero-posterior axis of the cut proximal tibia using both the ROM and the TTL technique during primary TKA without postoperative clinical assessment. Computer navigation was used to measure this difference in 20 consecutive knees of 20 patients who underwent a posterior stabilized total knee arthroplasty with a fixed-bearing polyethylene insert and a patella resurfacing. The ROM technique is a repeatable method with an interclass correlation coefficient (ICC2) of 0.84 (p < 0.001). The trial tibial baseplate was on average 4.56 degrees externally rotated compared to the tubercle landmark. This difference was statistically significant (p = 0.028). The amount of maximum intra-operative flexion and the pre-operative mechanical axis were positively correlated with the magnitude of difference between the two methods. It is important for the orthopaedic surgeon to realise that there is a significant difference between the TTL technique and ROM technique when positioning the tibial component in a rotational position. This difference is correlated with high maximum flexion and mechanical axis deviations.Keywords
This publication has 46 references indexed in Scilit:
- The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesisInternational Orthopaedics, 2013
- Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial borderBMC Musculoskeletal Disorders, 2010
- Early Revision for Component Malrotation in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- Synchronisation of tibial rotational alignment with femoral component in total knee arthroplastyInternational Orthopaedics, 2007
- Determining the rotational alignment of the tibial component at total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Relaxing the Rule of Ten Events per Variable in Logistic and Cox RegressionAmerican Journal of Epidemiology, 2006
- Statistics in orthopaedic papersThe Journal of Bone and Joint Surgery. British volume, 2006
- Accuracy of a computer-assisted navigation system for total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2006
- The effect of component placement on knee kinetics after arthroplasty with an unconstrained prosthesisJournal of Orthopaedic Research, 2001
- Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1985