Haemodynamic Effects of Food Intake during Haemodialysis
Authors:
- Murugan SivalingamMSMurugan Sivalingam
- Anindya BanerjeeABAnindya Banerjee
- Gail NevettGNGail Nevett
- Ken FarringtonKFKen Farrington
- 29 January 2008
- journal article
- clinical trial
- Published by S. Karger AG in Blood Purification
- Vol. 26 (2) , 157-162
Abstract
Background: There is some doubt whether food intake during haemodialysis (HD) is detrimental to haemodynamic stability. Methods: We studied 20 stable non-diabetic HD patients during a single session. A standard meal was given 45 min into dialysis. Relative blood volume (RBV), cardiac output (CO), systemic vascular resistance (SVR) and extracellular fluid (ECF) resistance were monitored continuously. Total protein and albumin were measured. Results: There was a significant reduction in RBV after food ingestion (maximum reduction 3.4 ± 1.1%; p < 0.001). There was no significant change in ECF resistance, heart rate, CO or SVR. Mean arterial pressure was significantly different from pre-food levels 30 min after food (p = 0.04). The rate of change of total protein and albumin concentration was significantly higher immediately after food ingestion. Conclusions: Food intake during HD caused significant reductions in RBV, possibly related to fluid shifts from intestinal microcirculation to interstitium. CO and SVR remained stable perhaps because of the opposing effects of food ingestion and UF.Keywords
This publication has 11 references indexed in Scilit:
- The haemodynamic response to submaximal exercise during isovolaemic haemodialysisNephrology Dialysis Transplantation, 2004
- The Relationship Between Systemic and Whole-Body Hematocrit Is Not Constant during Ultrafiltration on HemodialysisJournal of the American Society of Nephrology, 2004
- Changes in major blood components after adopting the supine position during haemodialysisNephrology Dialysis Transplantation, 2001
- Cardiac and hemodynamic effects of hemodialysis and ultrafiltrationAmerican Journal of Kidney Diseases, 2000
- Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterizationCritical Care Medicine, 2000
- Cardiac Output and Central Blood Volume During Hemodialysis: MethodologyAdvances in Renal Replacement Therapy, 1999
- Postprandial Hypotension: Epidemiology, Pathophysiology, and Clinical ManagementAnnals of Internal Medicine, 1995
- Postprandial Blood Pressure Changes During HemodialysisAmerican Journal of Kidney Diseases, 1988
- Postprandial alterations in hemodynamics and blood pressure in normal subjectsThe American Journal of Cardiology, 1986
- Hemodynamic and Humoral Effects of Caffeine in Autonomic FailureNew England Journal of Medicine, 1985