Parametric Study of Blade Tip Clearance, Flow Rate, and Impeller Speed on Blood Damage in Rotary Blood Pump
Authors:
- 27 May 2009
- journal article
- Published by Wiley in Artificial Organs
- Vol. 33 (6) , 468-474
Abstract
Phenomenological studies on mechanical hemolysis in rotary blood pumps have provided empirical relationships that predict hemoglobin release as an exponential function of shear rate and time. However, these relations are not universally valid in all flow circumstances, particularly in small gap clearances. The experiments in this study were conducted at multiple operating points based on flow rate, impeller speed, and tip gap clearance. Fresh bovine red blood cells were resuspended in phosphate-buffered saline at about 30% hematocrit, and circulated for 30 min in a centrifugal blood pump with a variable tip gap, designed specifically for these studies. Blood damage indices were found to increase with increased impeller speed or decreased flow rate. The hemolysis index for 50-microm tip gap was found to be less than 200-microm gap, despite increased shear rate. This is explained by a cell screening effect that prevents cells from entering the smaller gap. It is suggested that these parameters should be reflected in the hemolysis model not only for the design, but for the practical use of rotary blood pumps, and that further investigation is needed to explore other possible factors contributing to hemolysis.Keywords
This publication has 25 references indexed in Scilit:
- A novel formulation for blood trauma prediction by a modified power-law mathematical modelBiomechanics and Modeling in Mechanobiology, 2005
- The Power‐law Mathematical Model for Blood Damage Prediction: Analytical Developments and Physical InconsistenciesArtificial Organs, 2004
- Investigation of fluid dynamics within a miniature mixed flow blood pumpExperiments in Fluids, 2001
- Investigation of flow and material induced hemolysis with a Couette type high shear systemMaterialwissenschaft und Werkstofftechnik, 2001
- Experimental Study of the Dependence of Hemolysis Level on the Design of Artificial Cardiac ValvesBiomedical Engineering, 2001
- A Mathematical Model for Shear‐Induced HemolysisArtificial Organs, 1995
- Three‐Dimensional Numerical Prediction of Stress Loading of Blood Particles in a Centrifugal PumpArtificial Organs, 1995
- “Shear induced platelet activation” - A critical reappraisalBiorheology, 1985
- A Couette viscometer for short time shearing of bloodBiorheology, 1980
- Red Blood Cell Damage by Shear StressBiophysical Journal, 1972