Plume Propagation Direction Determination with SO2 Cameras
Authors:
Preprint
- 28 October 2016
- preprint
- Published by Copernicus GmbH in EGUsphere
- Vol. 2016, 1-18
Abstract
SO2 cameras are becoming an established tool for measuring sulphur dioxide (SO2) fluxes in volcanic plumes with good precision and high temporal resolution. The primary result of SO2 camera measurements are time series of two-dimensional SO2 column density distributions (i.e. SO2 column density images). However it is frequently overlooked that in order to determine the correct SO2 fluxes, not only the SO2 column density, but also the distance between the camera and the volcanic plume have to be precisely known. This is because cameras only measure angular extensions of objects while flux measurements require knowledge of the spatial plume extension. The distance to the plume may vary within the image array (i.e. the field of view of the SO2 camera) since the plume propagation direction (i.e. the wind direction) might not be parallel to the image plane of the SO2 camera. If the wind direction and thus the camera-plume distance is not well known, this error propagates into the determined SO2 fluxes and can cause errors exceeding 50 %. This is a source of error which is independent of the frequently quoted (approximate) compensation of apparently higher SO2 column densities and apparently lower plume propagation velocities at non-perpendicular plume observation angles. Here, we propose a new method to estimate the propagation direction of the volcanic plume directly from SO2 camera image time series by analysing apparent flux gradients along the image plane. From the plume propagation direction and the known location of the SO2 source (i.e. volcanic vent) and camera position the camera-plume distance can be determined. Besides being able to determine the plume propagation direction, and thus the wind direction in the plume region, directly from SO2 camera images, we additionally found, that it is possible to detect changes of the propagation direction at a time resolution on the order of minutes. In addition to theoretical studies we applied our method to SO2 flux measurements at Mt. Etna and demonstrate that we obtain considerably more precise (up to a factor of 2 error reduction) SO2 fluxes. We conclude that studies on SO2 flux variability become more reliable by excluding the possible influences of propagation direction variations.Keywords
All Related Versions
- Published version: Atmospheric Measurement Techniques, 10 (3), 979.
This publication has 17 references indexed in Scilit:
- An automated SO 2 camera system for continuous, real-time monitoring of gas emissions from Kīlauea Volcano's summit Overlook CraterJournal of Volcanology and Geothermal Research, 2015
- Validation of the SO 2 camera for high temporal and spatial resolution monitoring of SO 2 emissionsJournal of Volcanology and Geothermal Research, 2015
- Quantitative imaging of volcanic plumes — Results, needs, and future trendsJournal of Volcanology and Geothermal Research, 2015
- Intercomparison of SO 2 camera systems for imaging volcanic gas plumesJournal of Volcanology and Geothermal Research, 2015
- Gas emission strength and evolution of the molar ratio of BrO/SO2 in the plume of Nyiragongo in comparison to EtnaJournal of Geophysical Research: Atmospheres, 2014
- Differential Absorption Spectroscopy2008
- A miniaturised ultraviolet spectrometer for remote sensing of SO2 fluxes: a new tool for volcano surveillanceJournal of Volcanology and Geothermal Research, 2003
- Tropospheric sulfur dioxide observed by the ERS‐2 GOME instrumentGeophysical Research Letters, 1998
- The applications of optical correlation techniques to the remote sensing of SO2 plumes using sky lightAtmospheric Environment (1967), 1971
- Prediction of volcanic eruption by measuring the chemical composition and amounts of gasesBulletin of Volcanology, 1963