Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot study
Authors:
- 12 March 2024
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 26 (3) , 615-620
Abstract
Aim: In this pilot study, the fracture resistance of hybrid abutments with different restoration lengths was investigated.Materials and Methods: Sixteen monolithic zirconia restorations of an upper right incisor were designed to fit a titanium base abutment. Eight central incisors had a crown length of 8 mm (T1) and the other half a length of 12 mm (T2). All crowns were cemented on the titanium base using a resin cement. After cementation, the samples were placed in a thermocycler for 5000 cycles. Fracture strength was measured using a universal test machine. Deformations and fractures of the samples were investigated.Results: The mean fracture resistance of T1 was 515 N (SD 96 N, 339–650) and 305 N (SD 57 N, 234–408) for T2 (p < 0.001). Both groups showed deformation of the titanium base, with no significant difference between both groups (p = 0.200). A difference in fracture type (p = 0.013) was observed, with significantly more screw fractures occurring in group T1 (p = 0.026).Conclusion: Within the limitations of this study, hybrid restorations with standard titanium base abutments can withstand forces that have been associated with chewing, irrespective of the crown length. However, the shorter crowns demonstrated more fatal fractures.Keywords
This publication has 21 references indexed in Scilit:
- The influence of titanium base abutments on peri‐implant soft tissue inflammatory parameters and marginal bone loss: A randomized clinical trialClinical Implant Dentistry and Related Research, 2020
- Clinical evaluation of two-piece zirconia abutments with bonded titanium inserts for implant-supported restorationsThe Journal of Prosthetic Dentistry, 2020
- Effect of CAD/CAM Abutment Height and Cement Type on the Retention of Zirconia CrownsImplant Dentistry, 2018
- Retention of zirconia on titanium in two-piece abutments with self-adhesive resin cementsThe Journal of Prosthetic Dentistry, 2018
- Comparison of fracture strength and failure mode of different ceramic implant abutmentsThe Journal of Prosthetic Dentistry, 2017
- Load to failure of different zirconia abutments for an internal hexagon implantThe Journal of Prosthetic Dentistry, 2015
- The effect of zirconia or titanium as abutment material on soft peri‐implant tissues: a systematic review and meta‐analysisClinical Oral Implants Research, 2015
- In vitro performance of zirconia and titanium implant/abutment systems for anterior applicationJournal of Dentistry, 2014
- Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant‐Supported RestorationsClinical Implant Dentistry and Related Research, 2013
- Retentive Strength of Two‐Piece CAD/CAM Zirconia Implant AbutmentsClinical Implant Dentistry and Related Research, 2013