Bacterial Contamination in Dental Unit Water Lines at Primary Health Care Centers (2022–2023): A Nationwide Study
Preprint
- 30 July 2025
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background: Dental unit water lines (DUWLs) can harbor microbial contamination, posing risks for cross-infection to patients and dental staff. This study assessed the prevalence of bacterial contamination in DUWLs at primary healthcare centers in Kuwait during 2022–2023 and examined variation by year, governorate, and sampling outlet. Methods: A retrospective cross-sectional analysis was conducted using 3,290 water test results from six governorates. Data were obtained from the Environmental Health Department, Ministry of Health, and analyzed using STATA 17. Contamination was defined as a total plate count (TPC) >100 CFU/mL or presence of coliforms, Escherichia coli, Pseudomonas aeruginosa, or fecal streptococci. Descriptive and logistic regression analyses were performed. Results: Overall contamination prevalence was 16.8%. Rates were higher in 2023 (19.8%) than in 2022 (13.7%), and higher in Mubarak Al-Kabeer governorate (23%) and cup filler outlets (18.9%). Logistic regression showed significantly increased odds of contamination in 2023 (OR = 1.6; 95% CI: 1.3–2.0), Mubarak Al-Kabeer (OR = 1.4; 95% CI: 1.1–1.9), and cup fillers (OR = 1.3; 95% CI: 1.1–1.6). P. aeruginosa was detected in 1.3% of samples. Conclusion: One in six DUWL samples exceeded Kuwait’s strict microbial safety threshold. Findings highlight spatial and procedural variations in contamination and underscore the need for enhanced disinfection protocols, preventive maintenance, and targeted staff training to ensure waterline safety.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- The effect of different types of water sources on dental unit waterline contamination: A systematic review and meta analysisHeliyon, 2024
- Dental unit waterline infection control practice and knowledge gapsThe Journal of the American Dental Association, 2024
- The importance of biofilm contamination control for dental unit waterlines: a multicenter assessment of the microbiota diversity of biofilm in dental unit waterlinesJournal of Oral Microbiology, 2023
- First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management programJournal of Oral Microbiology, 2023
- The microbiological load and microbiome of the Dutch dental unit; ‘please, hold your breath’Water Research, 2021
- Effectiveness and safety of low-concentrated ozonized water for the reduction of contamination in dental unit water linesHeliyon, 2019
- Pyrosequencing analysis of bacterial diversity in dental unit waterlinesWater Research, 2015
- Update on infectious risks associated with dental unit waterlinesFEMS Immunology & Medical Microbiology, 2012
- Biofilm problems in dental unit water systems and its practical controlJournal of Applied Microbiology, 2009
- Reducing Bacterial Counts in Dental Unit Waterlines: Distilled Water vs. Antimicrobial AgentsJournal of the California Dental Association, 2002