New Hip Adductor Isometric Strength Test on Force Platform Shows Good and Acceptable Intra-Test Reliability for Peak Force Measurement
Authors:
- Pablo Merino-MuñozPMPablo Merino-Muñoz
- Felipe Hermosilla-PalmaFelipe Hermosilla-Palma
- Nicolás Gómez-ÁlvarezNGNicolás Gómez-Álvarez
- Jorge Pérez-ContrerasJPJorge Pérez-Contreras
- Bianca MiarkaBMBianca Miarka
- Carlos Gomes de OliveiraCOCarlos Gomes de Oliveira
- Ciro José BritoCBCiro José Brito
- Luciano Luporini MenegaldoLMLuciano Luporini Menegaldo
- Kristof KippKKKristof Kipp
- Esteban Aedo-MuñozEsteban Aedo-Muñoz
Open Access
- 10 April 2025
- journal article
- research article
- Published by MDPI AG in Biomechanics
- Vol. 5 (2) , 23
Abstract
Background/Objectives: Groin and hip injuries are common in sport, and muscle weakness has been identified as an intrinsic risk factor. So, analyzing the strength of the hip musculature becomes important. To date, there are no hip adductor isometric strength tests on force platforms. This study aims to analyze the intra-test reliability of a hip adductor strength test using force platforms. Methods: The study sample comprised 13 male professional soccer players with an average age of 22.3 ± 3 years, body mass of 75.8 ± 5.4 kg, and height of 1.8 ± 0.1 m. Assessments were conducted on a uniaxial force platform. The variables analyzed are peak force (PF), rate of force development (RFD), and impulse. Intra-test reliability was evaluated using the coefficient of variation (CV), intraclass correlation coefficient (ICC), and Bland–Altman plots. Results: Acceptable levels of reliability were identified solely for the variable of peak force, with CV values of D = 5.7% for the dominant profile and ND = 5.4% for the non-dominant profile. Furthermore, moderate and good relative reliability were observed in peak force for the dominant (ICC = 0.706) and non-dominant (ICC = 0.819) profiles, respectively. However, the remaining time-related variables, RFD and impulse, did not achieve acceptable levels of absolute reliability (CV > 10%) and displayed poor to moderate relative reliability. Conclusions: In summary, PF during the hip adductor isometric strength test demonstrated acceptable absolute and commendable relative reliability. Conversely, the time-related variables, specifically RFD and impulse, yielded unsatisfactory absolute and relative reliability levels.Keywords
Funding Information
- Universidad Adventista de Chile (169)
This publication has 39 references indexed in Scilit:
- Intra-day and inter-day reliabilities of the 0° and 45° adductor squeeze tests using hand-held dynamometrySport Sciences for Health, 2022
- In-season monitoring of hip and groin strength, health and function in elite youth soccer: Implementing an early detection and management strategy over two consecutive seasonsJournal of Science and Medicine in Sport, 2018
- Intraclass correlation coefficients: clearing the air, extending some cautions, and making some requestsHealth Services and Outcomes Research Methodology, 2016
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Rate of force development: physiological and methodological considerationsEuropean Journal of Applied Physiology, 2016
- Assessment of the rate of force development scaling factor for the hip musclesMuscle & Nerve, 2014
- World Medical Association Declaration of HelsinkiJAMA, 2013
- EMG of the hip adductor muscles in six clinical examination testsPhysical Therapy in Sport, 2012
- Hip adductor muscle strength is reduced preceding and during the onset of groin pain in elite junior Australian football playersJournal of Science and Medicine in Sport, 2010
- Reliability of handheld dynamometry in assessment of hip strength in adult male football playersJournal of Science and Medicine in Sport, 2010