Occupational exposure to inhalable and total aerosol in the primary nickel production industry.
Authors:
- J H VincentJVJ H Vincent
- G WahlGWG Wahl
- G MaldonadoGMG Maldonado
- 1 December 1995
- journal article
- research article
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 52 (12) , 793-799
Abstract
This paper describes a study that was carried out in the primary nickel production industry to investigate the levels of personal exposure to aerosols containing nickel and the impact on exposure assessment of introducing new personal sampling techniques with performance consistent with the latest particle size-selective criteria. Experiments were carried out at workplaces in mining, milling, smelting, and refining works to investigate the effect of changing from the current method of total aerosol (with the widely used 37 mm filter holder) to the new method of measuring inhalable aerosol (with the Institute of Occupational Medicine (IOM) inhalable aerosol sampler). The results show that inhalable aerosol exposure concentrations--for both overall aerosol and for total nickel--were consistently and significantly higher than the corresponding total aerosol concentrations. Weighted least squares linear regression yielded IOM/37 mm factors ranging from about 1.2 to 4.0. The exposure data for each company process were found to be log-normally distributed. The results suggest the possibility of generating a single pragmatic factor for each company process for converting current total aerosol exposures to new exposures based on the inhalability concept contained in the latest particle size-selective criteria for aerosol exposure assessment. Such data may be important in determining new occupational exposure limits for nickel.Keywords
This publication has 7 references indexed in Scilit:
- Progress towards implementation of new aerosol industrial hygiene standards, with special reference to the aluminium industryScience of The Total Environment, 1995
- Sampling of inhalable aerosol with special reference to speciationThe Analyst, 1995
- 23.O.05 Wind tunnel testing of the sampling efficiency of personal inhalable aerosol samplersJournal of Aerosol Science, 1994
- A MEASURE OF GOODNESS-OF-FIT FOR THE LOGNORMAL MODEL APPLIED TO OCCUPATIONAL EXPOSURESAIHA Journal, 1991
- THE USE OF DUST-COLLECTING CASSETTES IN DUST SAMPLERSAnnals of Occupational Hygiene, 1990
- ENTRY CHARACTERISTICS OF PRACTICAL WORKPLACE AEROSOL SAMPLERS IN RELATION TO THE ISO RECOMMENDATIONSAnnals of Occupational Hygiene, 1990
- A NEW PERSONAL SAMPLER FOR AIRBORNE TOTAL DUST IN WORKPLACESAnnals of Occupational Hygiene, 1986