Single-Drop and Nanogram Level Determination of Sulfite (SO32−) in Alcoholic and Nonalcoholic Beverage Samples Based on Diffuse Reflectance Fourier Transform Infrared Spectroscopic (DRS-FTIR) Analysis on KBr Matrix
Authors:
- 25 September 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 55 (21) , 8319-8324
Abstract
The diffuse reflectance Fourier transform spectroscopic (DRS-FTIR) method, using potassium bromide matrix, has been developed for the one-drop microdetermination of sulfite in beverage samples. The present method is very simple, rapid, and precise for the determination of sulfite. The nanogram level of sulfite determination is based on the selection of a quantitative analytical peak at 495 cm−1 among the three observed vibrational peaks obtained by diffuse reflectance Fourier transform infrared spectroscopy (DRS-FTIR). As little as a single drop of sample is sufficient for quantitative analysis of sulfite. The limit of detection (LOD) and the limit of quantification (LOQ) of the method are found to be 8 and 40 ng of SO32− 0.1 g−1 of KBr matrix, respectively. The linear range of the method (LR) as well as the LOD based on the concentration of sulfite in the solution are 5–500 and 0.8 µg/mL, respectively. The precision in terms of standard deviation and relative standard deviation value at a level of 100 ng of SO32− 0.1 g−1 of KBr for n = 10 are found to be 2 ng of SO32− and 2.3%, respectively. The relative standard deviation (n = 10) for the determination of sulfite in beverage samples available in the local market was observed to be in the range of 2.4–7.8%. The method is free from interionic effects of foreign species. No sample pretreatment is required in this method. The proposed method avoids the requirement of large numbers and bulk amounts of reagents. The method is well-suited to the need of green chemistry.Keywords
This publication has 42 references indexed in Scilit:
- Nondestructive and rapid determination of nitrate in soil, dry deposits and aerosol samples using KBr-matrix with diffuse reflectance Fourier transform infrared spectroscopy (DRIFTS)Analytica Chimica Acta, 2007
- Novel spectrofluorimetric method for the determination of sulfite with rhodamine B hydrazide in a micellar mediumAnalytica Chimica Acta, 2002
- Determination of sulfur dioxide and ascorbic acid in beverages using a dual channel flow injection electrochemical detection systemAnalytica Chimica Acta, 2000
- Sulfide measurements by flow injection analysis and ion chromatography with electrochemical detectionAnalytica Chimica Acta, 2000
- Chemiluminescence of sulfite based on auto-oxidation sensitized by rhodamine 6GAnalytica Chimica Acta, 1999
- Optical sensing of sulfite with a phosphorescent probeAnalytica Chimica Acta, 1998
- Determination of sulphite in wines by gas-diffusion flow injection analysis utilizing spectrophotometric pH-detectionAnalytica Chimica Acta, 1997
- Flow-injection analysis with chemiluminescent detection of sulphite using Na2CO3NaHCO3-Cu2+ systemAnalytica Chimica Acta, 1996
- A Fluorimetric Method for the Determination of Atmospheric Sulphur Dioxide With 2′, 7′—Dichlorofluorescein∗Analytical Letters, 1995
- Determination of Sulfite Ion by Using Microbial SensorAnalytical Letters, 1992