ANCILLARY EQUIPMENT TO INCREASE QUALITY AND REDUCE RADIATION EXPOSURE IN THE EQUINE NUCLEAR MEDICINE LABORATORY
Authors:
- Charleen RomineCRCharleen Romine
- 1 September 2000
- journal article
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 41 (5) , 470-475
Abstract
The construction of ancillary equipment used to improve image quality and reduce personnel radiation exposure in the equine nuclear medicine laboratory is illustrated. The devices include a self supporting lead sheet for shielding the distal limb or limb pair, a hanging lead sheet for shielding the proximal limb, a lead square for shielding the urinary bladder or jugular catheter, a restraining board for acquiring a palmar view of the foot, a head support to stabilize the head for imaging and a head support for stabilizing the neck for imaging. The restraining board and head supports decrease patient motion, improve image quality, and decrease the number of repeat acquisitions so that the time to perform the complete study is shortened. The self supporting shielding device allows the handlers to increase their distance from the horse which enhances radiation safety.Keywords
This publication has 2 references indexed in Scilit:
- Radiation hazards from horses undergoing scintigraphy using technetium −99mEquine Veterinary Journal, 1997
- Rules, regulations and safety aspects of scintigraphyEquine Veterinary Education, 1995