Aneurysm Sac Pressure Measurement with a Pressure Sensor in Endovascular Aortic Aneurysm Repair
Authors:
- 1 September 2006
- journal article
- review article
- Published by SAGE Publications in Vascular
- Vol. 14 (5) , 264-269
Abstract
Aortic endograft surveillance is a necessity for the lifetime of a patient owing to the risk of endoleaks and device complications. The current standard of care for surveillance is radiologic imaging. The most commonly used modality is computed tomographic angiography. Magnetic resonance angiography and ultrasonography have also been used as surveillance tools. These imaging techniques have risks and limitations, and alternative surveillance tools are being investigated. Remote pressure sensing is a promising technology that can provide adjunctive support to the current imaging modalities. The technology is applicable to both abdominal and thoracic endograft implantation and surveillance. It has recently gained clearance from the US Food and Drug Administration for acute aneurysm exclusion during an abdominal endograft insertion. As more data are accumulated, it may be possible for remote pressure sensing to replace current imaging techniques as the sole modality for endograft surveillance.Keywords
This publication has 26 references indexed in Scilit:
- Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurementJournal of Vascular Surgery, 2006
- Effect of intraluminal thrombus on pressure transmission in the abdominal aortic aneurysmJournal of Vascular Surgery, 2005
- Noninvasive measurement of aortic aneurysm sac tension with vibrometryJournal of Vascular Surgery, 2005
- Computational analysis of biomechanical contributors to possible endovascular graft failureBiomechanics and Modeling in Mechanobiology, 2005
- Aneurysm shrinkage after endovascular repair of aortic diseasesClinical Imaging, 2005
- Infrarenal Abdominal Aortic Aneurysm Complicated by Persistent Endotension After Endovascular Repair: Report of a CaseSurgery Today, 2005
- Intrasac Pressure Waveforms After Endovascular Aneurysm Repair (EVAR) are a Reliable Marker of Type I Endoleaks, but not Type II or Combined Types: An Experimental StudyEuropean Journal of Vascular and Endovascular Surgery, 2004
- Durability and Validity of a Remote, Miniaturized Pressure Sensor in an Animal Model of Abdominal Aortic AneurysmJournal of Endovascular Therapy, 2004
- Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: differences between shrinking, unchanged, and expanding aneurysms with and without endoleaksJournal of Vascular Surgery, 2004
- Aneurysm pressure following endovascular exclusionEuropean Journal of Vascular and Endovascular Surgery, 1997