Analytical Possibilities of Total Reflection X-ray Spectrometry (TXRF) for Trace Selenium Determination in Soils
- 18 August 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (18) , 7744-7751
Abstract
Selenium content of soils is an important issue due to the narrow range between the nutritious requirement and toxic effects upon Se exposure. However, its determination is challenging due to low concentrations within complex matrices that hamper the analysis in most spectroscopic techniques. In this study, we explored the possibilities of several analytical approaches combined with total reflection X-ray (TXRF) spectrometry for soil Se determinations. The direct analysis of a solid suspension using 20 mg of fine ground material (<50 μm) has a relatively high Se limit of detection (LOD) of 1 mg/kg (worldwide Se average in soils = 0.4 mg/kg) and is therefore only suitable for seleniferous soils. Several fast and simple analytical strategies were developed to decrease matrix effects and improve the LOD for Se determination in soil digests. On one hand, the application of a liquid−liquid extraction procedure using ethyl ether and the introduction of a Cr absorbent in the instrument configuration were carried out to avoid the associated problems on TXRF analysis of soil extracts due to the high Fe concentrations (∼700 mg/L). On the other hand, a dispersive liquid−liquid microextraction procedure (DLLME) before the TXRF analysis of the soil digest was also developed. The effects of various experimental parameters such as sample volume, effect of major elements present in the soil matrix (Fe), and Se concentration in the sample were investigated. The LOD using this analytical methodology (0.05 mg/kg of Se) was comparable to or lower than those obtained in previous works using other popular spectrometric techniques such as GFAAS, ICPMS, and AFS. The calculated Se concentration for JSAC-0411 ([Se] = 1.32 ± 0.27 mg/kg) using the combination of DLLME and TXRF ([Se] = 1.40 ± 0.23 mg/kg) was in agreement with the certified value.Keywords
This publication has 37 references indexed in Scilit:
- Preconcentration Methods for the Analysis of Liquid Samples by X-Ray Fluorescence TechniquesApplied Spectroscopy Reviews, 2010
- Separation and preconcentration system based on ultrasonic probe-assisted ionic liquid dispersive liquid–liquid microextraction for determination trace amount of chromium(VI) by electrothermal atomic absorption spectrometryTalanta, 2010
- Preconcentration and speciation of arsenic in water specimens by the combination of solidification of floating drop microextraction and electrothermal atomic absorption spectrometryTalanta, 2010
- Aqua regia extractable selenium concentrations of some Scottish topsoils measured by ICP‐MS and the relationship with mineral and organic soil componentsJournal of the Science of Food and Agriculture, 2010
- Recent development in liquid phase microextraction for determination of trace level concentration of metals—A reviewAnalytica Chimica Acta, 2010
- Sample Preparation For X ‐Ray Fluorescence Analysis2009
- Slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of As and Se in soil and sludgeAnalytica Chimica Acta, 2007
- Determination of selenium in water and soil by hydride generation atomic absorption spectrometry using solid reagentsTalanta, 2005
- Determination of Selenium Concentration in Sixty Five Reference Materials for Geochemical Analysis by GFAAS after Separation with Thiol CottonGeostandards Newsletter, 2001
- Soil, grain and water chemistry in relation to human selenium-responsive diseases in Enshi District, ChinaApplied Geochemistry, 2000