Two-step camera calibration method based on the SPGD algorithm
Authors:
- 10 September 2012
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (26) , 6421-6428
Abstract
Given the rapid convergence characteristic of the stochastic parallel gradient descent (SPGD) algorithm, this study proposes a method that applies the algorithm to a two-step camera calibration method to resolve the frequent iteration and long calibration time deficiencies that exist under the traditional two-step camera calibration method, thereby achieving rapid calibration. The method first uses image coordinates obtained with subpixel positioning technology as initial values of control variables, in addition to positive disturbances produced on a two-dimensional plane, then uses two-step theory to calculate the average value of aberrations. Based on the same rationale, negative disturbances are then produced and the average value of the aberrations is calculated. Finally if, after assessing whether to continue with further iterations based on the difference in these values, continued iterations confirm new control variables based on the SPGD algorithm iteration formula, a new cycle is started until the results satisfy requirements. Theoretical analysis and experimental results show that the proposed rapid calibration method using the SPGD algorithm in the two-step camera calibration method is 3–4 times faster than the traditional two-step calibration method, and that it has significant potential value for use in certain time-constrained projects.Keywords
Funding Information
- National Natural Science Foundation of China (40901215, 11002156)
- Foundation of the National University of Defense Technology
This publication has 21 references indexed in Scilit:
- Introduction to Stochastic Search and Optimization2003
- In defence of the 8-point algorithm2002
- Self-Calibration of Stationary CamerasInternational Journal of Computer Vision, 1997
- Euclidean reconstruction from image sequences with varying and unknown focal length and principal point1997
- A self-calibration technique for active vision systemsIEEE Transactions on Robotics and Automation, 1996
- The modulus constraint: a new constraint self-calibration1996
- Projective reconstruction and invariants from multiple imagesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1994
- Camera calibration with distortion models and accuracy evaluationIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- A theory of self-calibration of a moving cameraInternational Journal of Computer Vision, 1992
- A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lensesIEEE Journal on Robotics and Automation, 1987