A case of anaphylactic shock induced by FX60 polysulfone hemodialyzer but not F6‐HPS polysulfone hemodialyzer
- 13 June 2014
- journal article
- case report
- Published by Wiley in Hemodialysis International
- Vol. 18 (4) , 841-845
Abstract
A 75‐year‐old woman was admitted for dyspnea and fever. She underwent emergent dialysis smoothly under F6‐HPS polysulfone hemodialyzer. With two subsequent hemodialysis sessions, severe anaphylactic reaction with cardiopulmonary resuscitation occurred under FX60 polysulfone dialyzer. Further dialysis sessions by F6‐HPS polysulfone dialyzer were uneventful. This rare case demonstrated that dialyzer reaction may be markedly different even with the same material and the same manufacturer.Keywords
This publication has 18 references indexed in Scilit:
- Anaphylactic reaction induced by a polysulfone/polyvinylpyrrolidone membrane in the 10th session of hemodialysis with the same dialyzerHemodialysis International, 2011
- High‐Flux Dialyzers, Backfiltration, and Dialysis Fluid QualitySeminars in Dialysis, 2011
- Contact allergies in haemodialysis patients: a prospective study of 75 patientsAllergy, 2009
- Haemodialysis‐associated anaphylactic and anaphylactoid reactionsAllergy, 2006
- Dialyzer reactions in a patient switching from peritoneal dialysis to hemodialysisHemodialysis International, 2005
- The lymphocyte transformation test in the diagnosis of drug hypersensitivityAllergy, 2004
- Drug provocation testing in the diagnosis of drug hypersensitivity reactions: general considerationsAllergy, 2003
- High-Permeable Membranes and Hypersensitivity-Like Reactions: Role of Dialysis Fluid ContaminationBlood Purification, 1990
- Complement Activation and Hypersensitivity Reactions to Dialysis MembranesNew England Journal of Medicine, 1984
- Anaphylactoid reactions due to haemodialysis, haemofiltration, or membrane plasma separation.BMJ, 1982