We present a simulation method and results that utilizes accurate electromagnetic field simulations to study the maximum allowable transmitted power levels from in vivo devices to achieve a required bit error rates (BER) at the external node (receiver) while maintaining the specific absorption rate (SAR) under a required threshold. The BER of the communication can be calculated using the derived power threshold for a given modulation scheme. These results can be used to optimize the transmitted power levels while assuring that the safety guidelines in terms of the resulting SAR of transmitters placed in any location inside the human body are met. To evaluate the SAR and BER, a software-based test bench that allows an easy way to implement field solver solutions directly into system simulations was developed. To demonstrate the software-based test bench design, a complete OFDM-based communication (IEEE 802.11g) for the in vivo environment was simulated. Results showed that for cases when noise levels increase or the BER becomes more stringent, a relay network or the use of multiple receive antennas, such as in a MIMO system, will be become necessary to achieve high data rate communication.Keywords
This publication has 7 references indexed in Scilit:
- Analysis of the correlation between antenna gain and SAR Levels inside the human head model at 900MHz2012
- In vivo wireless communication channels2012
- MARVEL IN VIVO WIRELESS VIDEO SYSTEMTechnology and Innovation, 2012
- New approaches to reliable wireless body area networks2011
- Spectrum-Based Health Monitoring for Self-Adaptive Systems2011
- Body Area Networks: A SurveyMobile Networks and Applications, 2010
- SAR Analysis in Dispersive Tissues for In Vivo UWB Body Area Networks2009