A New Fluorescence Turn-on Assay for Trypsin and Inhibitor Screening Based on Graphene Oxide
Authors:
- 10 March 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 3 (4) , 1175-1179
Abstract
In this paper, we describe a new continuous fluorescence turn-on method for trypsin assay and inhibitor screening in situ. This assay is designed based on the following assumptions: (1) It is expected that the fluorescein-labeled peptide composed of six arginine residues (Arg6-FAM) with positive charges will interact with the negatively charged edge of water-soluble graphene oxide (GO) because of electrostatic interactions to form a GO/Arg6-FAM complex. As a result, the fluorescence of fluorescein will be quenched because of the energy transfer from fluorescein to GO. (2) Arg6-FAM can be hydrolyzed into small fragments in the presence of trypsin, and accordingly, the GO/Arg6-FAM complex will be dissociated, gradually leading to fluorescence recovery for the solution. In this way, the trypsin activity can be easily assayed with the ensemble of Arg6-FAM and GO. Additionally, the ensemble can be employed for screening of the inhibitors of trypsin.Keywords
This publication has 50 references indexed in Scilit:
- The role of trypsin, trypsin inhibitor, and trypsin receptor in the onset and aggravation of pancreatitisJournal of Gastroenterology, 2006
- A turbidimetric method for measuring the activity of trypsin and its inhibitionAnalytical Biochemistry, 2006
- Efficient and Specific Trypsin Digestion of Microgram to Nanogram Quantities of Proteins in Organic−Aqueous Solvent SystemsAnalytical Chemistry, 2005
- Trypsin Cleaves Exclusively C-terminal to Arginine and Lysine ResiduesMolecular & Cellular Proteomics, 2004
- Fast-Response Proteomics by Accelerated In-Gel Digestion of ProteinsAnalytical Chemistry, 2003
- High-Throughput Peptide Mass Mapping Using a Microdevice Containing Trypsin Immobilized on a Porous Polymer Monolith Coupled to MALDI TOF and ESI TOF Mass SpectrometersJournal of Proteome Research, 2002
- Extensive Investigation of Patients with Mild Elevations of Serum Amylase and/or Lipase Is ‘Low Yield’Canadian Journal of Gastroenterology and Hepatology, 2002
- Underestimation of acute pancreatitis: patients with only a small increase in amylase/lipase levels can also have or develop severe acute pancreatitisGut, 1999
- An Assay for Detecting Nanogram Levels of Proteolytic EnzymesAnalytical Biochemistry, 1995
- Activation of pancreatic zymogensDigestive Diseases and Sciences, 1986