Distractive Force Relative to Initial Graft Compression in an In Vivo Anterior Cervical Discectomy and Fusion Model
- 1 March 2010
- journal article
- biomechanics
- Published by Wolters Kluwer Health in Spine
- Vol. 35 (5) , 526-530
Abstract
Study Design. An in vivo biomechanical anterior cervical discectomy and instrumented fusion (ACDFI) model employing a calibrated distractor and a subminiature load cell used to intraoperatively measure distractive force across the discectomy site and subsequent compressive force across the interbody load cell following distractor removal. Objective. To determine the relationship between the distractive force and resultant initial graft compression in an in vivo ACDFI model. Summary of Background Data. The relationship between the distractive force and subsequent graft compression following distractor removal has not been studied in an in vivo ACDFI model. The consequences of over or under distraction and its subsequent effect on graft compression with regards to axial neck pain, endplate failure with graft subsidence, and fusion rates is an area of clinical significance for ACDFI. Methods. Intraoperative measurements were obtained from 17 discectomy sites in 12 patients undergoing one and two level ACDFI. Informed consent was obtained from all subjects before surgery. A calibrated Caspar distractor was used to measure the distraction across the discectomy site and a subminiature interbody load cell was placed into the discectomy site and used to measure the resultant initial compressive force following distractor removal. The statistical significance and correlation between the distractive force across the discectomy site and the subsequent compressive force across the load cell were investigated with the Pearson correlation coefficient. Results. The average distractive force across the discectomy site was 33.5 ± 11.6 lbs and the subsequent compressive force across the interbody load cell was 16.9 ± 5.9 lbs following distractor removal. The Pearson correlation coefficient was r = 0.912 (P < 0.0005). The data showed a statistically significant linear correlation between the distractive force and the subsequent compressive force across the range of distraction investigated. Conclusion. This study demonstrated a statistically significant linear correlation between the distractive force applied across the discectomy site and the subsequent compressive force across a load cell placed in the interbody space following distractor removal in an in vivo ACDFI model.Keywords
This publication has 10 references indexed in Scilit:
- Effects of Disc Height and Distractive Forces on Graft Compression in an Anterior Cervical Corpectomy ModelSpine, 2008
- Development and calibration of a load sensing cervical distractor capable of withstanding autoclave sterilizationMedical Engineering & Physics, 2004
- Effects of Disc Height and Distractive Forces on Graft Compression in an Anterior Cervical Discectomy ModelSpine, 2002
- A Prospective Comparison of the Standard and Reverse Robinson Cervical Grafting Techniques: Radiographic and Clinical AnalysesJournal of Spinal Disorders, 2000
- Anterior Cervical FusionSpine, 2000
- Biomechanical Analysis of Facet and Graft Loading in a Smith-Robinson Type Cervical Spine ModelSpine, 1994
- Ideal Thickness of Smith—Robinson Graft for Anterior Cervical FusionSpine, 1993
- Anterior Cervical Discectomy, Fusion, and PlatingSpine, 1993
- Biomechanical Considerations in the Surgical Management of Cervical Spondylotic MyelopathySpine, 1988
- The Vertical Stability of the Cervical SpineSpine, 1988