Cost‐effective immobilization for whole brain radiation therapy
Authors:
- Ashley E. RubinsteinARAshley E. Rubinstein
- Brian M. AndersonBABrian M. Anderson
- Skylar S. GaySGSkylar S. Gay
- Rachel E. McCarrollRMRachel E. McCarroll
- Constance A. OwensCOConstance A. Owens
- Tucker J. NethertonTNTucker J. Netherton
- Kelly D. KislingKKKelly D. Kisling
- Laurence E. CourtLCLaurence E. Court
- Jinzhong YangJinzhong Yang
Open Access
- 6 June 2017
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 18 (4) , 116-122
Abstract
To investigate the inter‐ and intra‐fraction motion associated with the use of a low‐cost tape immobilization technique as an alternative to thermoplastic immobilization masks for whole‐brain treatments. The results of this study may be of interest to clinical staff with severely limited resources (e.g., in low‐income countries) and also when treating patients who cannot tolerate standard immobilization masks. Setup reproducibility of eight healthy volunteers was assessed for two different immobilization techniques. (a) One strip of tape was placed across the volunteer's forehead and attached to the sides of the treatment table. (b) A second strip was added to the first, under the chin, and secured to the table above the volunteer's head. After initial positioning, anterior and lateral photographs were acquired. Volunteers were positioned five times with each technique to allow calculation of inter‐fraction reproducibility measurements. To estimate intra‐fraction reproducibility, 5‐minute anterior and lateral videos were taken for each technique per volunteer. An in‐house software was used to analyze the photos and videos to assess setup reproducibility. The maximum intra‐fraction displacement for all volunteers was 2.8 mm. Intra‐fraction motion increased with time on table. The maximum inter‐fraction range of positions for all volunteers was 5.4 mm. The magnitude of inter‐fraction and intra‐fraction motion found using the “1‐strip” and “2‐strip” tape immobilization techniques was comparable to motion restrictions provided by a thermoplastic mask for whole‐brain radiotherapy. The results suggest that tape‐based immobilization techniques represent an economical and useful alternative to the thermoplastic mask.Keywords
This publication has 28 references indexed in Scilit:
- Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patientsRadiation Oncology, 2013
- The accuracy of frameless stereotactic intracranial radiosurgeryRadiotherapy and Oncology, 2010
- Trend analysis of radiation therapy incidents over seven yearsRadiotherapy and Oncology, 2010
- The management of radiation treatment error through incident learningRadiotherapy and Oncology, 2010
- Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation systemRadiation Oncology, 2010
- Ultrasound Imaging to Assess Inter- and Intra-fraction Motion during Bladder Radiotherapy and its Potential as a Verification ToolClinical Oncology, 2009
- Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray PositioningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Cone Beam CT Image Guidance for Intracranial Stereotactic Treatments: Comparison With a Frame Guided Set-UpInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Time Dependence of Intrafraction Patient Motion Assessed by Repeat Stereoscopic ImagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Palliative Radiation Therapy in the Management of Brain Metastases, Spinal Cord Compression, and Bone MetastasesSeminars in Interventional Radiology, 2007