Comparison of PACS and Hard-copy 51-inch Radiographs for Measuring Leg Length and Deformity
Open Access
- 1 January 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (1) , 244-250
Abstract
The picture archiving and communication system (PACS) eventually will replace the use of standard hard-copy radiographs. It is unknown whether measurements of limb length discrepancy (LLD) and deformity on PACS compare in accuracy and reproducibility with those from hard-copy radiographs. We compared the reproducibility and reliability of LLD and deformity measurements for each of these two media. We retrospectively reviewed 51-inch standing lower extremity images obtained for LLD or deformity analysis from 40 patients to compare the measurements and their reliability on hard-copy film with those performed on soft-copy PACS. Two observers independently performed measurements twice using each system at 1-week intervals to minimize interobserver or intraobserver bias. Intraclass correlation coefficients (ICCs) were determined to test intraobserver and interrater reliability of Rater 1 and Rater 2. Interrater reliability of measurements made on hard copy ranged from 0.69 to 0.99 and PACS-derived measurements ranged from 0.66 to 0.98. Intraobserver reliability for Rater 1 for measurements made on hard copy ranged from 0.853 to 0.999 and PACS-derived measurements ranged from 0.80 to 0.996. Intraobserver reliability for Rater 2 for measurements made on hard copy ranged from 0.931 to 0.999 and PACS-derived measurements ranged from 0.962 to 0.999. Each system yielded comparable reliability for measurements, therefore, transition to PACS to perform measurements in patients with LLD or deformity can be made with confidence. Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 12 references indexed in Scilit:
- Alignment and articular orientation of lower limbs: manual vs computer-aided measurements on digital radiograms.2005
- Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographsEuropean Radiology, 2004
- A comparison of conventional film, CR hard copy and PACS soft copy images of the chest: analyses of ROC curves and inter-observer agreementEuropean Journal of Radiology, 2003
- Accuracy of Interpretation of CT Scans: Comparing PACS Monitor Displays and Hard-Copy ImagesAmerican Journal of Roentgenology, 2002
- Orthopaedic measurements with computed radiography. Methodological development, accuracy, and radiation dose with special reference to the weight-bearing lower extremity and the dislocating patella.2001
- Fracture interpretation using electronic presentation: A comparisonJournal of Digital Imaging, 2000
- PACS in sonography: accuracy of interpretation using film compared with monitor display. Picture archiving and communication systems.American Journal of Roentgenology, 1999
- Reporting requirements for skeletal digital radiography: comparison of soft-copy and hard-copy presentation.Radiology, 1998
- Computed Radiography for Characterisation of the Weight-Bearing KneeActa Radiologica, 1997
- Computed radiographic imaging: use in low-dose leg length radiographyAmerican Journal of Roentgenology, 1987