Biomechanical Effect of Coronal Alignment and Ligament Laxity in Total Knee Arthroplasty: A Simulation Study
Open Access
- 11 April 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 851495
Abstract
The purposes of this study were to develop a cruciate-retaining total knee arthroplasty musculoskeletal model, which enables the adjustment of ligament length and implant alignment; validate the model; and evaluate the effects of varus/valgus alignment adjustment and unbalanced medial/lateral ligament laxity during gait. A cruciate-retaining total knee arthroplasty musculoskeletal model was constructed and validated against the in vivo contact forces. This model was transformed to 2° varus/valgus alignment of femoral or tibial replacement models and 2° medial/lateral laxity models. The contact forces and ligament tensions of the adjusted models were calculated. The contact forces in the model showed good agreement with the in vivo contact forces. Valgus replacement alignment with balanced ligament models showed a lower contact force at the medial compartment than at the neutral alignment model, whereas the varus replacement alignment with balanced ligament models showed a greater contact force at the medial compartment and medial/posterior cruciate ligament tension. The medial laxity with neutral alignment model showed a similar contact force with decreased medial ligament tension compared to the balanced neutral alignment model, whereas the lateral laxity with the neutral alignment model showed a greater contact force and decreased lateral ligament tension. The cruciate-retaining total knee arthroplasty model was validated using in vivo contact forces (r = 0.939) Two degrees of valgus alignment adjustment with balanced ligament or neutral alignment with 2° of medial laxity can be safe without increasing contact force or ligament tension compared to neutral alignment with a balanced extension gap. However, 2° of varus alignment adjustment with balanced ligament or neutral alignment with 2° of lateral laxity may be unfavorable due to the overloading of the joints and knee ligaments.Keywords
This publication has 36 references indexed in Scilit:
- Grand challenge competition to predict in vivo knee loadsJournal of Orthopaedic Research, 2011
- Neutral Mechanical Alignment: A Requirement for Successful TKA: AffirmsOrthopedics, 2011
- Enlarged post-operative posterior condyle tightens extension gap in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2011
- Coronal Alignment in Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- Good Alignment After Total Knee Arthroplasty Leads to Faster Rehabilitation and Better FunctionThe Journal of Arthroplasty, 2009
- The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- Robot-assisted Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- An implantable telemetry device to measure intra-articular tibial forcesJournal of Biomechanics, 2005
- The effect of valgus/varus malalignment on load distribution in total knee replacementsJournal of Biomechanics, 2005
- Articular contact in a three-dimensional model of the kneeJournal of Biomechanics, 1991