Simultaneous endoscopic ultrasound-guided hepaticogastrostomy and bridging stenting with partial stent-in-stent method
Authors:
- 15 April 2020
- journal article
- editorial
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 52 (10) , E381-E382
Abstract
Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is used increasingly worldwide as an alternative to endoscopic retrograde cholangiopancreatography (ERCP) for biliary drainage. The HGS route is used for drainage in cases of hilar malignant biliary obstruction [1] [2] [3] [4]. However, no studies have reported on drainage of all hilar branches via the HGS route in cases that require stenting of the right anterior and right posterior sectional ducts. We report on a patient with inoperable gallbladder cancer causing hilar obstruction in whom ERCP was not possible. In a single procedure, we performed EUS-HGS and hilar stenting of the right anterior and right posterior sectional ducts using the partial stent-in-stent method ([Video 1]). Video 1 Novel simultaneous drainage of all branches for hilar malignant obstruction using endoscopic ultrasound-guided hepaticogastrostomy and bridging stenting with a partial stent-in-stent method. A 66-year-old woman with unresectable gallbladder cancer had duodenal and biliary obstruction. After placing a metal duodenal stent, we performed EUS-HGS. After puncturing the B3 segment using EUS, bile duct enhancement showed hilar obstruction (Bismuth type IIIa) ([Fig. 1]). Therefore, we performed simultaneous drainage of all branches through the HGS route. We inserted guidewires (Visiglide2; Olympus, Tokyo, Japan) into B8 and B6 in parallel. We then inserted the first stent (8 × 60 mm uncovered, self-expandable metal stent [SEMS]; Zeo stent V; ZEON Medical Inc., Kawasaki, Japan) from B8 to the left hepatic duct. We then manipulated the guidewire for the first stent through the stent mesh and into B6, running parallel with the existing B6 guidewire. The deployed first stent was dilated using a balloon dilator (REN, 8-mm wide; Kaneka Medix Corporation, Tokyo, Japan), and then the second stent (8 × 60 mm uncovered SEMS; Zeo stent V) was deployed from B6 to the left hepatic duct using a partial stent-in-stent method ([Fig. 2]). Finally, we inserted the third stent (8 × 80 mm fully covered SEMS; X suit NIR; Olympus) from B3 to the stomach through the HGS route ([Fig. 3]). No adverse events occurred during the procedure. Endoscopy_UCTN_Code_TTT_1AS_2ADKeywords
This publication has 3 references indexed in Scilit:
- Endoscopic Ultrasound-Guided Biliary Drainage for Unresectable Hilar Malignant Biliary ObstructionClinical Endoscopy, 2019
- Drainage of the right liver under EUS guidance: A bridge technique allowing drainage of the right liver through the left liver into the stomach or jejunumEndoscopic Ultrasound, 2019
- Is EUS-guided drainage a suitable alternative technique in case of proximal biliary obstruction?Therapeutic Advances in Gastroenterology, 2017