Evaluation of Methods That Locate the Center of the Ankle for Computer-assisted Total Knee Arthroplasty
Authors:
- Aaron C DaubADAaron C Daub
- Nicholas J GioriNGNicholas J Giori
- Stuart B GoodmanStuart B Goodman
- Scott L DelpSDScott L Delp
- 1 October 2005
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 439 (&NA;) , 129-135
Abstract
Accurate alignment of the mechanical axis of the limb is important to the success of a total knee arthroplasty. Although computer-assisted navigation systems can align implants more accurately than traditional mechanical guides, the ideal technique to determine the distal end point of the mechanical axis, the center of the ankle, is unknown. In this study, we evaluated the accuracy, precision, objectivity, and speed of five anatomic methods and two kinematic methods for estimating the ankle center in 11 healthy subjects. Magnetic resonance images were used to characterize the shape of the ankle and establish the true ankle center. The most accurate and precise anatomic method was establishing the midpoint of the most medial and most lateral aspects of the malleoli (4.5 ± 4.1 mm lateral error; 2.7 ± 4.5 mm posterior error). A biaxial model of the ankle (2.0 ± 6.4 mm medial error; 0.3 ± 7.6 mm anterior error) was the most accurate kinematic method. Establishing the midpoint of the most medial and most lateral aspects of the malleoli was an accurate, precise, objective, and fast method for establishing the center of the ankle.Keywords
This publication has 15 references indexed in Scilit:
- Evaluation of Accuracy in Ankle Center Location for Tibial Mechanical Axis IdentificationJournal of Investigative Surgery, 2004
- How Accurate is Current TKR Instrumentation?Clinical Orthopaedics and Related Research, 2003
- Computer Assisted Knee ReplacementClinical Orthopaedics and Related Research, 1998
- Posterior tilting of the tibial component decreases femoral rollback in posterior‐substituting knee replacement: A computer simulation studyJournal of Orthopaedic Research, 1998
- In vivo determination of the anatomical axes of the ankle joint complex: An optimization approachJournal of Biomechanics, 1994
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- Prediction of total knee motion using a three-dimensional computer-graphics modelJournal of Biomechanics, 1990
- Tibial anatomy and functional axesJournal of Orthopaedic Research, 1989
- Design of Dyads with helical, cylindrical, spherical, revolute and prismatic jointsMechanism and Machine Theory, 1972
- On the Screw Axes and Other Special Lines Associated With Spatial Displacements of a Rigid BodyJournal of Engineering for Industry, 1967