Novel Hybrid Filter for the Treatment of Septic Tank Effluent
Open Access
- 1 July 2006
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 132 (7) , 764-768
Abstract
Intermittent sand filtration is a common and effective method for treating septic tank effluent. However, if the loading rate is too high, clogging and ponding of the sand filter surface layer can occur due to the accumulation of excessive biomass and the deposition of suspended solids. This ponding limits the practicality of sand filtration as it makes it necessary to take the filter out of service for maintenance. The objective of this study was to develop and test, on-site, a new hybrid filter system that would reduce the risk of clogging at an organic loading rate substantially greater than the maximum recommended loading rate for intermittent sand filters. The system comprised a deep horizontal flow biofilm reactor (HFBR) over a deep stratified sand filter. The HFBR consisted of a stack of 20 horizontal corrugated polyvinyl chloride sheets, at vertical spacings. The sheets were arranged so that the wastewater flowed over and back along alternate sheets down through the stack. The main biofilm growth formed on these sheets. The hybrid filter was loaded with septic tank effluent from an office/garage complex at the rate of for a period of 400 days in two phases. During the first phase, the effluent volume of was applied in 24 doses/day for , and during the second phase in 6 doses/day for . Biofilms in the HFBR substantially reduced the organic and suspended solids loads that reached the sand filter surface and allowed an average total biochemical oxygen demand loading rate, based on HFBR plan area, of to be applied to the system without clogging. This rate was substantially greater than the maximum recommended loading rate of for intermittent sand filters. During both loading phases a removal of 94% was achieved and nitrification was nearly complete. The average effluent was during both phases. The hybrid filter system appeared to perform better in terms of suspended solids handling and nitrification during the more frequent dosing phase. The hybrid filtration system offers a more compact alternative to intermittent sand filtration on its own with little risk of clogging.
Keywords
This publication has 7 references indexed in Scilit:
- Surface Clogging in an Intermittent Stratified Sand FilterSoil Science Society of America Journal, 2004
- Transport phenomena in intermittent filtersWater Science & Technology, 1997
- Soil clogging in vertical flow reed beds mechanisms, parameters, consequences and.......solutions?Water Science & Technology, 1997
- Dynamic Behavior of Intermittent Buried FiltersWater Science & Technology, 1993
- Evaluation of On‐Site Waste Disposal System for Nitrogen ReductionJournal of Environmental Engineering, 1989
- Wastewater‐Induced Soil Clogging DevelopmentJournal of Environmental Engineering, 1987
- Column Studies of Soil Clogging in a Slowly Permeable Soil as a Function of Effluent QualityJournal of Environmental Quality, 1974