Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring
Authors:
- Frank KrummenauerFKFrank Krummenauer
- Philipp HackerPHPhilipp Hacker
- N. PfeifferNPN. Pfeiffer
- Burkhard H. DickBDBurkhard H. Dick
- 1 October 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (10) , 1915-1920
Abstract
To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage. Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometric characteristics such as axial length (AL) and anterior chamber depth were determined. Primary clinical end points were capsular bag size and capsulorhexis diameter measured intraoperatively and by means of slitlamp biomicroscopy and retroillumination photography postoperatively. There were no clinically relevant group differences in AL, anterior chamber depth, or capsulorhexis diameter. Eyes implanted with the CBR showed shrinkage of the capsular bag from 10.6 to 10.4 mm after a median of 3 months (sign test; P = .023); eyes with a CTR showed comparable median capsular bag shrinkage from 10.5 to 10.2 mm (P<.001), whereas eyes without a CTR showed a median shrinkage from 10.5 to 10.0 mm (P<.001). Intraindividual shrinkage was of a similar, although significantly different, order among these groups (median shrinkage 0.15 versus 0.23 and 0.38 mm, respectively; all pairwise Wilcoxon test; P = .050, P = .020, P<.001, respectively). Capsular shrinkage can be inhibited by a CBR and, to lesser extent, a CTR; the gain in shrinkage prevention is limited when compared with a CMR, however. This conclusion can be drawn only for the specific CBR or CTR and hydrophobic acrylic intraocular lens (IOL) used in this study. Reduction of capsular bag shrinkage after CTR implantation may reduce IOL dislocation and tilt and help to maintain postoperative visual acuity.Keywords
This publication has 21 references indexed in Scilit:
- Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantationJournal of Cataract & Refractive Surgery, 2003
- Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgeryJournal of Cataract & Refractive Surgery, 2002
- Capsular bending ring to prevent posterior capsule opacification: 2 year follow-upJournal of Cataract & Refractive Surgery, 2001
- Lens implant selection with absence of capsular supportCurrent Opinion in Ophthalmology, 2001
- Implantation of the modified endocapsular bending ring in pediatric cataract surgery using a viscoadaptive viscoelastic agentJournal of Cataract & Refractive Surgery, 1999
- Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixationJournal of Cataract & Refractive Surgery, 1998
- Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate) capsule tension ringJournal of Cataract & Refractive Surgery, 1997
- Endocapsular ring approach to the subluxed cataractous lensJournal of Cataract & Refractive Surgery, 1995
- Posterior capsule opacificationSurvey of Ophthalmology, 1992
- Ocular Manifestations in the Marfan Syndrome and HomocystinuriaAmerican Journal of Ophthalmology, 1973