Explore how immobilization strategies affected immunosensor performance by comparing four methods for antibody immobilization on electrode surfaces
Authors:
Open Access
- 23 December 2022
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Abstract
Among the common methods used for antibody immobilization on electrode surfaces, which is the best available option for immunosensor fabrication? To answer this question, we first used graphene-chitosan-Au/Pt nanoparticle (G-Chi-Au/PtNP) nanocomposites to modify a gold electrode (GE). Second, avian reovirus monoclonal antibody (ARV/MAb) was immobilized on the GE surface by using four common methods, which included glutaraldehyde (Glu), 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide/N-hydroxysuccinimide (EDC/NHS), direct incubation or cysteamine hydrochloride (CH). Third, the electrodes were incubated with bovine serum albumin, four different avian reovirus (ARV) immunosensors were obtained. Last, the four ARV immunosensors were used to detect ARV. The results showed that the ARV immunosensors immobilized via Glu, EDC/NHS, direct incubation or CH showed detection limits of 100.63 EID50 mL−1, 100.48 EID50 mL−1, 100.37 EID50 mL−1 and 100.46 EID50 mL−1 ARV (S/N = 3) and quantification limits of 101.15 EID50 mL−1, and 101.00 EID50 mL−1, 100.89 EID50 mL−1 and 100.98 EID50 mL−1 ARV (S/N = 10), respectively, while the linear range of the immunosensor immobilized via CH (0–105.82 EID50 mL−1 ARV) was 10 times broader than that of the immunosensor immobilized via direct incubation (0–104.82 EID50 mL−1 ARV) and 100 times broader than those of the immunosensors immobilized via Glu (0–103.82 EID50 mL−1 ARV) or EDC/NHS (0–103.82 EID50 mL−1 ARV). And the four immunosensors showed excellent selectivity, reproducibility and stability.Keywords
Funding Information
- Youth Science Fund Project in Guangxi (2020GXNSFBA297104)
- Guangxi Science and Technology projects (AB21076004)
- Guangxi BaGui Scholars Program Foundation (2019A50)
This publication has 33 references indexed in Scilit:
- A method for high-throughput, sensitive analysis of IgG Fc and Fab glycosylation by capillary electrophoresisJournal of Immunological Methods, 2015
- Chitosan coated on the layers’ glucose oxidase immobilized on cysteamine/Au electrode for use as glucose biosensorBiosensors and Bioelectronics, 2014
- Oriented antibody immobilization by site-specific UV photocrosslinking of biotin at the conserved nucleotide binding site for enhanced antigen detectionBiosensors and Bioelectronics, 2013
- Magnetic gold nanoparticles in SERS-based sandwich immunoassay for antigen detection by well oriented antibodiesBiosensors and Bioelectronics, 2013
- Improving immunosensor performance through oriented immobilization of antibodies on carbon nanotube composite surfacesBiosensors and Bioelectronics, 2013
- (R)-Lipo-Diaza-18-Crown-6 Self-Assembled Monolayer as a Selective Serotonin ReceptorAnalytical Chemistry, 2009
- A novel electrochemical immunosensor based on hydrogen evolution inhibition by enzymatic copper deposition on platinum nanoparticle-modified electrodeBiosensors and Bioelectronics, 2008
- Reduction of severe bovine serum associated matrix effects on carboxymethylated dextran coated biosensor surfacesTalanta, 2008
- Contrasting glycosylation profiles between Fab and Fc of a human IgG protein studied by electrospray ionization mass spectrometryJournal of Immunological Methods, 2007
- Cell Impedance Measurement by Laplace Transformation of Charge or Discharge Current–VoltageJournal of the Electrochemical Society, 2006