Abstract
CoCrMo-based metal-on-metal hip implants experienced unexpectedly high failure rates despite the high wear and corrosion resistance of the bulk material. Although they exhibit a lower volumetric wear compared to other implant materials, CoCrMo-based implants produced a significantly larger 'number' of smaller wear particles. CoCrMo is nominally an extremely stable material with high Cr content providing passivity. However, despite the Co:Cr ratio in the original alloy being 2:1; chemical analyses of wear particles from periprosthetic tissue have found the particles to be composed predominately of Cr species, with only trace amounts of Co remaining. Here a correlative spectroscopy and microscopy approach has shown that these particles dissolve via a non-stoichiometric, and geometrically inhomogeneous, mechanism similar to de-alloying. This mechanism is previously unreported for this material and was not apparent in any of the regulatory required tests, suggesting that such tests are insufficiently discriminating.Keywords
This publication has 27 references indexed in Scilit:
- Evidence for the dissolution of molybdenum during tribocorrosion of CoCrMo hip implants in the presence of serum proteinActa Biomaterialia, 2016
- Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfacesActa Biomaterialia, 2009
- Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluidsCorrosion Science, 2008
- Total hip arthroplasties: What are the reasons for revision?International Orthopaedics, 2007
- Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titaniumActa Biomaterialia, 2006
- The role of macrophages in osteolysis of total joint replacementBiomaterials, 2005
- Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplastyThe Journal of Arthroplasty, 2004
- Size, shape, and composition of wear particles from metal–metal hip simulator testing: Effects of alloy and number of loading cyclesJournal of Biomedical Materials Research Part A, 2003
- Metal wear particle characterization from metal on metal total hip replacements: Transmission electron microscopy study of periprosthetic tissues and isolated particlesJournal of Biomedical Materials Research, 1998
- In-vitro corrosion and wear of titanium alloys in the biological environmentBiomaterials, 1996