Shaping ability of Hero 642 rotary nickel–titanium instruments in simulated root canals: Part 1
- 1 May 2000
- journal article
- research article
- Published by Wiley in International Endodontic Journal
- Vol. 33 (3) , 248-254
Abstract
Aim: To determine the general efficacy and shaping ability of Hero 642 nickel–titanium rotary instruments during the preparation of simulated canals. Part 1 of this two‐part report describes the efficacy of the instruments in terms of three‐dimensional canal form.Methodology: A total of 40 simulated root canals made up of four different shapes in terms of angle and position of curvature were prepared by Hero 642 instruments using a crown‐down preparation sequence. The efficacy of the instruments was assessed in terms of preparation time, instrument failure, canal blockages and loss of canal length. Intra‐canal impressions were taken of the prepared canals in order to assess three‐dimensional canal form.Results: The mean time for canal preparation was 8.6 min and was influenced significantly (P < 0.05) by canal shape. Two instruments fractured and eight instruments deformed; significant differences were observed between canal shapes (P < 0.05). All of the canals remained patent. Fifteen canals (39.5%) maintained the correct working distance, 15 lost distance and eight canals gained length. Examination of intracanal impressions demonstrated that the majority of canals (79%) had apical stops; canal shape had a significant influence (P < 0.001) on the quality of apical stops. With one exception all canals had smooth canal walls and all of the canals showed good flow characteristics. Taper was poor in 30 canals (79%) and good in eight canals (21%).Conclusions: Hero 642 rotary nickel–titanium instruments prepared simulated canals rapidly but with a three‐dimensional form that lacked adequate taper.Keywords
This publication has 22 references indexed in Scilit:
- Shaping ability of Profile rotary nickel‐titanium instruments with ISO sized tips in simulated root canals: Part 1International Endodontic Journal, 1998
- A comparison of stainless steel Flexofiles and nickel‐titanium NiTiFlex files during the shaping of simulated canalsInternational Endodontic Journal, 1997
- A comparison of canal preparation with nickel-titanium and stainless steel instrumentsJournal of Endodontics, 1995
- A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instrumentsJournal of Endodontics, 1995
- Comparison of six files to prepare simulated root canals. Part 2International Endodontic Journal, 1992
- Comparison of six files to prepare simulated root canals. Part 1International Endodontic Journal, 1992
- A method for the construction of simulated root canals in clear resin blocksInternational Endodontic Journal, 1991
- A comparison of the ability of K‐files and Hedstrom files to shape simulated root canals in resin blocksInternational Endodontic Journal, 1989
- The effect of different files on the preparation shape of severely curved canalsInternational Endodontic Journal, 1985
- The use of rotary instruments as auxiliary aids to root canal preparation of molarsJournal of Endodontics, 1982