Intra- and inter-observer agreement in distal radius fracture dislocation measurement of casting position
Open Access
- 21 July 2023
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 94, 379-386
Abstract
Background and purpose: Most displaced distal radius fractures (DRF) are treated nonoperatively, with reduction and immobilization in a cast. Studies assessing intra- or inter-observer agreement on radiologic measurements of casting position have not been published, which was the aim of our study.Patients and methods: Our study is based on the Kuopio Osteoporosis Risk Factor and Prevention (OSTPRE) study. All detected DRFs during the OSTPRE follow-up were retrieved and based on sample size calculations 50 fractures were randomly selected for the study. 5 independent reviewers measured dislocation parameters and wrist position in a cast from the radiographs. A linear mixed model was used to estimate the concordance correlation coefficient (CCC) and total deviance index (TDI) that were used to evaluate intra- and inter-observer agreement. We used Kappa values to determine intra- and inter-rater agreement on radiographically acceptable reduction of the DRF. Limits of acceptable position were those defined by Finnish Current Care Guidelines.Results: For radial inclination, radial shortening, and dorsal/volar tilt, intra- and inter-observer correlations were high (CCC > 0.76). In addition, measurements of wrist angle in a splint had high correlations (CCC > 0.78), whereas measurement of intra-articular gap and step had poor correlations (CCC < 0.52). The Kappa value for overall agreement on the radiographically acceptable position of the DRF was modest (0.59).Conclusion: Intra- and inter-observer repeatability of casting position of radial inclination, radial shortening, and dorsal/volar tilt were high whereas intra-articular gap and step had poor correlations.Keywords
This publication has 16 references indexed in Scilit:
- Reliability of radiographic measurements for acute distal radius fracturesBMC Medical Imaging, 2016
- Is it really necessary to restore radial anatomic parameters after distal radius fractures?Injury, 2014
- Closed reduction of distal radius fractures: does instability mean irreducibility?Archives of orthopaedic and trauma surgery, 2013
- Radiological criteria for acceptable reduction of extra-articular distal radial fractures are not predictive for patient-reported functional outcomeJournal of Hand Surgery (European Volume), 2012
- The Epidemiology of Distal Radius FracturesHand Clinics, 2012
- Treatment of Distal Radius FracturesJournal of the American Academy of Orthopaedic Surgeons, 2010
- The Reliability of Measurements Taken from Computer-Stored Digitalised X-Rays of Acute Distal Radius FracturesJournal of Hand Surgery (European Volume), 2008
- Conservative interventions for treating distal radial fractures in adultsCochrane Database of Systematic Reviews, 2003
- X-ray film measurements for healed distal radius fracturesThe Journal of Hand Surgery, 1996
- Osteoporosis risk factors, gynaecological history and fractures in perimenopausal women — the results of the baseline postal enquiry of the Kuopio Osteoporosis Risk Factor and Prevention StudyMaturitas, 1993