Automatic MR volume registration and its evaluation for the pelvis and prostate
- 15 February 2002
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 47 (5) , 823-838
Abstract
A three-dimensional (3D) mutual information registration method was created and used to register MRI volumes of the pelvis and prostate. It had special features to improve robustness. First, it used a multi-resolution approach and performed registration from low to high resolution. Second, it used two similarity measures, correlation coefficient at lower resolutions and mutual information at full resolution, because of their particular advantages. Third, we created a method to avoid local minima by restarting the registration with randomly perturbed parameters. The criterion for restarting was a correlation coefficient below an empirically determined threshold. Experiments determined the accuracy of registration under conditions found in potential applications in prostate cancer diagnosis, staging, treatment and interventional MRI (iMRI) guided therapies. Images were acquired in the diagnostic (supine) and treatment position (supine with legs raised). Images were also acquired as a function of bladder filling and the time interval between imaging sessions. Overall studies on three patients and three healthy volunteers, when both volumes in a pair were obtained in the diagnostic position under comparable conditions, bony landmarks and prostate 3D centroids were aligned within 1.6 ± 0.2 mm and 1.4 ± 0.2 mm, respectively, values only slightly larger than a voxel. Analysis suggests that actual errors are smaller because of the uncertainty in landmark localization and prostate segmentation. Between the diagnostic and treatment positions, bony landmarks continued to register well, but prostate centroids moved towards the posterior 2.8–3.4 mm. Manual cropping to remove voxels in the legs was necessary to register these images. In conclusion, automatic, rigid body registration is probably sufficiently accurate for many applications in prostate cancer. For potential iMRI-guided treatments, the small prostate displacement between the diagnostic and treatment positions can probably be avoided by acquiring volumes in similar positions and by reducing bladder and rectal volumes.Keywords
This publication has 32 references indexed in Scilit:
- Robust registration method for interventional MRI-guided thermal ablation of prostate cancer2001
- Medical image registrationPhysics in Medicine & Biology, 2001
- Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatmentIEEE Transactions on Medical Imaging, 2000
- Prostate target volume variations during a course of radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998
- Automatic registration of pelvic computed tomography data and magnetic resonance scans including a full circle method for quantitative accuracy evaluationMedical Physics, 1998
- Visual assessment of the accuracy of retrospective registration of MR and CT images of the brainIEEE Transactions on Medical Imaging, 1998
- Accurate Registration of Serial 3D MR Brain Images and Its Application to Visualizing Change in Neurodegenerative DisordersJournal of Computer Assisted Tomography, 1996
- Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registrationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- Optimization of prostate carcinoma staging: Comparison of imaging and clinical methodsClinical Radiology, 1995
- Measurement of prostate movement over the course of routine radiotherapy using implanted markersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995