Abstract
High-resolution electron microscopy (HREM) combined with image reconstruction proves to be a powerful method in characterising thin amorphous films. For amorphous silicon (a-Si) it is shown that small variations in preparation conditions cause clear changes in the projected structure of the film, i.e. the size of nanocrystalline regions and the strength of density inhomogeneities in the nm range. On the other hand, some properties seem to be unique and independent of the preparation process (evaporation or glow discharge). These results have been obtained using a high-resolution electron microscope with a superconducting lens system. In order to obtain all the information from micrographs up to the information limit, a two-dimensional computer image-reconstruction method using several micrographs of a focus series was applied (EM-system). This method permits a detailed structural investigation with atomic resolution.