Cardiac Steady-State Free Precession CINE Magnetic Resonance Imaging at 3.0 Tesla
Authors:
- Bernd J. WinterspergerBWBernd J. Wintersperger
- Kerstin BaunerKBKerstin Bauner
- Scott B. ReederSRScott B. Reeder
- Denise FriedrichDFDenise Friedrich
- Olaf DietrichODOlaf Dietrich
- Katrin C. SprungKSKatrin C. Sprung
- Michele PiccioloMPMichele Picciolo
- Konstantin NikolaouKNKonstantin Nikolaou
- Maximilian F. ReiserMRMaximilian F. Reiser
- Stefan O. SchoenbergSSStefan O. Schoenberg
- 1 February 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 41 (2) , 141-147
Abstract
We sought to evaluate the impact of 3.0 T on accelerated CINE steady-state free precession (SSFP) regarding signal parameters and its volumetric accuracy. Ten individuals underwent cardiac CINE imaging at 1.5 T and 3.0 T using standard single-slice CINE and multislice TSENSE-accelerated CINE (5 slices/breath-hold) with 4-fold acceleration. Data were evaluated for left ventricular volumetric parameters (EDV, ESV, and EF) as well as for SNR and CNR. Phantom based data allowed for g-factor evaluation for estimation of noise levels for accelerated data sets. Volumetric results and signal parameters were compared with results of single-slice CINE SSFP at 1.5 T as standard of reference (SOR). Single-slice CINE at 3.0 T showed a approximately 90% increase in CNR compared with the SOR (P < 0.001). At 3.0 T, TSENSE CINE showed a less pronounced estimated loss in CNR (-58 +/- 6%) compared with single-slice CINE than at 1.5 T (-71 +/- 2%). 3.0 T TSENSE CINE showed a 21 +/- 18% lower CNR than the nonaccelerated 1.5 T CINE (P < 0.05). EF results for all data sets did not show any significant error while for EDV some errors have been encountered. 3.0 T permits compensation for the high CNR loss, which accompanies the 4-fold TSENSE acceleration at 1.5 T and shows volumetric accuracy. The use of parallel imaging may help to alleviate SAR limitations at higher field strength.Keywords
This publication has 30 references indexed in Scilit:
- Comprehensive Cardiac Magnetic Resonance Imaging at 3.0 TeslaInvestigative Radiology, 2006
- Practical approaches to the evaluation of signal‐to‐noise ratio performance with parallel imaging: Application with cardiac imaging and a 32‐channel cardiac coilMagnetic Resonance in Medicine, 2005
- Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithmEuropean Radiology, 2003
- Breath-hold FLASH and FISP Cardiovascular MR Imaging: Left Ventricular Volume Differences and ReproducibilityRadiology, 2002
- Assessment of Ventricular Function with Single Breath-Hold Real-Time Steady-State Free Precession Cine MR ImagingAmerican Journal of Roentgenology, 2002
- Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agentsJournal of Magnetic Resonance Imaging, 2001
- Steady‐state free precession magnetic resonance imaging of the heart: Comparison with segmented k‐space gradient‐echo imagingJournal of Magnetic Resonance Imaging, 2001
- Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State PrecessionRadiology, 2001
- Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)†Magnetic Resonance in Medicine, 2001
- MR Evaluation of Ventricular Function: True Fast Imaging with Steady-State Precession versus Fast Low-Angle Shot Cine MR Imaging: Feasibility StudyRadiology, 2001