Multiple Pounding Tuned Mass Damper (MPTMD) control on benchmark tower subjected to earthquake excitations
Authors:
- Wei LinWLWei Lin
- Yinglu LinYLYinglu Lin
- Gangbing SongGSGangbing Song
- Jun LiJun Li
- 25 December 2016
- journal article
- Published by Techno-Press in Earthquakes and Structures
- Vol. 11 (6) , 1123-1141
Abstract
Multiple Pounding Tuned Mass Damper (MPTMD) control on benchmark tower subjected to earthquake excitations pounding tuned mass damper (PTMD);pounding force model;vibration control;benchmark tower;earthquake excitation; To explore the application of traditional tuned mass dampers (TMDs) to the earthquake induced vibration control problem, a pounding tuned mass damper (PTMD) is proposed by adding a viscoelastic limitation to the traditional TMD. In the proposed PTMD, the vibration energy can be further dissipated through the impact between the attached mass and the viscoelastic layer. More energy dissipation modes can guarantee better control effectiveness under a suite of excitations. To further reduce mass ratio and enhance the implementation of the PTMD control, multiple PTMDs (MPTMD) control is then presented. After the experimental validation of the proposed improved Hertz based pounding model, the basic equations of the MPTMD controlled system are obtained. Numerical simulation is conducted on the benchmark model of the Canton Tower. The control effectiveness of the PTMD and the MPTMD is analyzed and compared under different earthquake inputs. The sensitivity and the optimization of the design parameters are also investigated. It is demonstrated that PTMDs have better control efficiency over the traditional TMDs, especially under more severe excitation. The control performance can be further improved with MPTMD control. The robustness can be enhanced while the attached mass for each PTMD can be greatly reduced. It is also demonstrated through the simulation that a non-uniformly distributed MPTMD has better control performance than the uniformly distributed one. Parameter study is carried out for both the PTMD and the MPTMD systems. Finally, the optimization of the design parameters, including mass ratio, initial gap value, and number of PTMD in the MPTMD system, is performed for control improvement.Keywords
This publication has 29 references indexed in Scilit:
- Structural damage identification with power spectral density transmissibility: numerical and experimental studiesSmart Structures and Systems, 2015
- Attenuation of a linear oscillator using a nonlinear and a semi-active tuned mass damper in seriesJournal of Sound and Vibration, 2013
- On the continuous contact force models for soft materials in multibody dynamicsMultibody System Dynamics, 2010
- Optimal design theories of tuned mass dampers with nonlinear viscous dampingEarthquake Engineering and Engineering Vibration, 2009
- Active and semi-active vibration control of buildings in Japan—Practical applications and verificationStructural Control and Health Monitoring, 2009
- Exploring the performance of a nonlinear tuned mass damperJournal of Sound and Vibration, 2009
- Optimal tuned mass damper for seismic applications and practical design formulasEngineering Structures, 2008
- Adaptive Tuned Mass Damper for the Construction of Concrete PiersStructural Engineering International, 2007
- Optimal design theories and applications of tuned mass dampersEngineering Structures, 2006
- Parametric study on multiple tuned mass dampers for buffeting control of Yangpu BridgeJournal of Wind Engineering and Industrial Aerodynamics, 2001