Vapor pressures of binary solutions composed of an alcohol (methanol, ethanol, allyl alcohol, 1-butanol, 2-butanol, 2-methyl-1-propanol, 1-pentanol, or 2-pentanol) and calcium chloride were measured at 298.15K using an apparatus based on a flow method coupled with gas chromatography. Measurements were carried out up to concentrated regions near the saturation concentration of calcium chloride. The error of measurement is estimated to be less than 2%. Further, the activities of alcohol were obtained from the vapor pressure data.