Control-Mode-Dependent dq-Impedance Modeling and Stability Analysis of Multi-Unit Alkaline Electrolysis Systems
Open Access
Abstract
Large alkaline-water-electrolysis plants are increasingly formed by multiple converter-fed electrolysis units operating in parallel, whose grid interaction is affected by both operating condition and Buck control mode. This paper develops a control-mode-dependent small-signal dq-impedance model for an IGBT rectifier–dc-link–Buck–alkaline-water-electrolyzer unit under constant-current (CC) and constant-power (CP) control. The complete Buck–AWE input impedances are retained, and the electrochemical operating point is recalculated with loading. Frequency-sweep simulations of all four dq-impedance elements reproduce the principal analytical magnitude and phase characteristics, validating the mode-dependent model. The unit admittances are then aggregated for arbitrary CC/CP combinations, and grid interaction is evaluated using the minimum impedance phase-difference margin at all magnitude crossings. For four 1 MW units at λ = 0.75 and SCR = 3, the margin increases from −22.95° for 4 CC to +4.42° for 4 CP. Parameter studies show that loading, grid strength, and CC/CP composition jointly determine the impedance-interaction screening margin. HIL tests further show that mode reconfiguration produces distinct coupled ac–dc–electrochemical transients. These tests are used as qualitative time-domain corroboration of the control-mode-dependent dynamics rather than as a quantitative validation of the numerical value of Mφ.Keywords
Funding Information
- State Grid Corporation of China (Grant No. 52018K25000N)
This publication has 22 references indexed in Scilit:
- Exploring the optimal size of grid-forming energy storage in an off-grid renewable P2H system under multi-timescale energy managementApplied Energy, 2026
- Power controller design for electrolysis systems with DC/DC interface supporting fast dynamic operation: A model-based and experimental studyApplied Energy, 2024
- Impedance modeling and stability analysis of electrolysis system for hydrogen production under weak gridFuel, 2024
- Overview of electrolyser and hydrogen production power supply from industrial perspectiveInternational Journal of Hydrogen Energy, 2023
- Extended load flexibility of utility-scale P2H plants: Optimal production scheduling considering dynamic thermal and HTO impurity effectsRenewable Energy, 2023
- Sequence Domain SISO Equivalent Models of a Grid-Tied Voltage Source Converter System for Small-Signal Stability AnalysisIEEE Transactions on Energy Conversion, 2017
- On the Equivalence and Impact on Stability of Impedance Modeling of Power Electronic Converters in Different DomainsIEEE Journal of Emerging and Selected Topics in Power Electronics, 2017
- Comprehensive Review of Stability Criteria for DC Power Distribution SystemsIEEE Transactions on Industry Applications, 2014
- Influencing factors of water electrolysis electrical efficiencyRenewable and Sustainable Energy Reviews, 2012
- Modeling of advanced alkaline electrolyzers: a system simulation approachInternational Journal of Hydrogen Energy, 2003