Balloon expandable stent implantation for native and recurrent coarctation of the aorta—prospective computed tomography assessment of stent integrity, aneurysm formation and stenosis relief
Authors:
- Damien KennyDKDamien Kenny
- Gareth MorganGMGareth Morgan
- Stephanie L CurtisSCStephanie L Curtis
- Mark C K HamiltonMHMark C K Hamilton
- Peter WildePWPeter Wilde
- Andrew J TometzkiATAndrew J Tometzki
- Mark S TurnerMTMark S Turner
- Robin P MartinRMRobin P Martin
Abstract
Background Stenting for aortic coarctation is known to be effective in the medium term. Aneurysm formation following stent implantation is a recognised complication. However, data regarding aortic wall injury and stent integrity following stent placement are sparse. Objectives We report comprehensive clinical, echocardiographic and prospective CT follow-up data following stenting for aortic coarctation from a single centre. Methods Full data analysis of all patients undergoing balloon expandable stent implantation and follow-up procedures in a single tertiary congenital cardiac unit. Results Between October 2002 and April 2008, we performed 102 coarctation stent procedures on 88 patients. Median age was 20.6 years (range 8.5–65) and median weight 65 kg (range 34–101). 94 stents (26 covered) were implanted. 12 procedures were re-dilatations. Stenting resulted in a reduction of the gradient across the site of coarctation, from a median of 20 mm Hg to 4 mm Hg. There were no procedure-related deaths. Four patients had immediate complications (one requiring emergency surgery). During median follow-up of 34.5 months (range 4.2–72.8), two patients had late complications requiring additional stent procedures. Follow-up CT data are available in 84 patients with MRI in one patient (96.5%). Only one patient developed a procedure-related aortic aneurysm. All stent fractures (n=7) occurred with a single stent design. Conclusions Stenting for aortic coarctation and re-coarctation is effective with low immediate complication rates. CT is useful in the longer term for assessment of stent integrity and post-procedural aneurysm formation. Overall incidence of post-procedural aneurysm is rare and stent fractures were not seen with newer generation stents.Keywords
This publication has 30 references indexed in Scilit:
- Stent Implantation for Adult Aortic CoarctationJACC, 2008
- Self‐expanding and balloon expandable covered stents in the treatment of aortic coarctation with or without aneurysm formationCatheterization and Cardiovascular Interventions, 2008
- Stenting complex aortic arch obstructionsCatheterization and Cardiovascular Interventions, 2008
- Impact of aortic stenting on peripheral vascular function and daytime systolic blood pressure in adult coarctationHeart, 2007
- Effect of endovascular stenting of aortic coarctation on biventricular function in adultsHeart, 2007
- Acute and intermediate outcomes, and evaluation of injury to the aortic wall, as based on 15 years experience of implanting stents to treat aortic coarctationCardiology in the Young, 2007
- Cancer risks following diagnostic and therapeutic radiation exposure in childrenPediatric Radiology, 2006
- Optimizing imaging after coarctation stenting: The clinical utility of multidetector computer tomographyCatheterization and Cardiovascular Interventions, 2005
- Comparison of 15 different stents in superficial femoral arteries by high resolution MRI ex vivo and in vivoJournal of Magnetic Resonance Imaging, 2005
- Transluminal aortic balloon angioplasty for coarctation of the aorta in the newbornAmerican Heart Journal, 1982