Pulsed Disc‐and‐Doughnut Column Performance

Authors:

Abstract
A study of the hydrodynamic variables, drop size, continuous phase axial dispersion, and mass‐transfer coefficients of a pulsed annular disc‐and‐doughnut liquid extraction column are presented for three different systems. The results indicate that the characteristic velocity plot of Gayler et al. (1953) can be used to describe the variation of holdup with flow rate for a range of pulsation velocities. The existence of several different operating regimes, namely streamline, mixer‐settler, and emulsion regimes, was observed when the input energy was altered. Mass‐transfer data from 72.5 mm i.d. and 2.5 m i.d. columns were interpreted in terms of the differential axial‐dispersion model; the number of transfer units in a unit length of column is proposed as the basis for scale‐up of the mass‐transfer performance. By considering the free areas in the column, a method is proposed for the geometric scale‐up of pulsed disc‐and‐doughnut columns.