Radiative Transfer Model Simulations for Ground-Based Microwave Radiometers in North China
Open Access
- 19 December 2021
- journal article
- research article
- Published by MDPI AG in Remote Sensing
- Vol. 13 (24) , 5161
Abstract
Ground-based microwave radiometer profilers (MWRPs) are widely used to provide high-temporal resolution atmospheric temperature and humidity profiles. The quality of the observed brightness temperature (TB) from MWRPs is key for retrieving accurate atmospheric profiles. In this study, TB simulations derived from a radiative transfer model (RTM) were used to assess the quality of TB observations. Two types of atmospheric profile data (conventional radiosonde and ERA5 reanalysis) were combined with the RTM to obtain TB simulations, then compared with corresponding observations from three MWRPs located in different places in North China to investigate the influence of input atmospheric profiles on TB simulations and evaluate the quality of TB observations from the three MWRPs. The comparisons of the matching samples under clear-sky conditions showed that TB simulations derived from both radiosonde and ERA5 profiles were very close to the TB observations from most of the MWRP channels; however, the correlation was lower and the bias was obvious at 51.26 GHz and 52.28 GHz, which indicates that the oxygen absorption component in the RTM needs to be improved for lower-frequency temperature channels. The difference in location of the radiosonde and MWRP sites affected the TB simulations for the water vapor channels, but had little impact on temperature channels that are insensitive to humidity. Comparisons of both simulations (ERA5 and Radiosonde) and the corresponding TB observations from the three sites indicated that the water vapor channels observation quality for the MWRP located in southern Beijing needs improvement. For the two types of profile data, ERA5 profiles have a more positive effect on TB simulations in the water vapor channels, such as enhanced consistence, reduced bias and standard deviation between simulations and observations for those MWRPs located away from the radiosonde station. Therefore, hourly ERA5 data are an optimal option in terms of compensating for limited radiosonde measurements and enhancing the monitoring quality of MWRP observations within 24 h.Keywords
Funding Information
- National Natural Science Foundation of China (41575033)
- National Key Research and Development Program of China ([2017YFC1501700])
- National Natural Science Foundation of China (41775005)
- Instrument Function Development Project of Chinese Academy of Sciences (E066193601)
This publication has 24 references indexed in Scilit:
- Application of a ground-based, multi-channel microwave radiometer to the alerting of low-level windshear at an airportMeteorologische Zeitschrift, 2011
- An evaluation of FY‐3A satellite data for numerical weather predictionQuarterly Journal of the Royal Meteorological Society, 2011
- Advances in Radiative Transfer Modeling in Support of Satellite Data AssimilationJournal of the Atmospheric Sciences, 2007
- Temperature and humidity profile retrievals from ground-based microwave radiometers during TUCMeteorologische Zeitschrift, 2006
- Validating clear air absorption models using ground-based microwave radiometers and vice-versaMeteorologische Zeitschrift, 2006
- Atmospheric radiative transfer modeling: a summary of the AER codesJournal of Quantitative Spectroscopy and Radiative Transfer, 2005
- A multichannel radiometric profiler of temperature, humidity, and cloud liquidRadio Science, 2003
- Water vapor microwave continuum absorption: A comparison of measurements and modelsRadio Science, 1998
- Cloud Layer Thicknesses from a Combination of Surface and Upper-Air ObservationsJournal of Climate, 1995
- Atmospheric 60-GHz oxygen spectrum: New laboratory measurements and line parametersJournal of Quantitative Spectroscopy and Radiative Transfer, 1992