Quantification and Detectability of In-Stent Stenosis with CT Angiography and MR Angiography in Arterial Stents In Vitro
Authors:
- Maria SchmookMSMaria Schmook
- Rüdiger SchernthanerRSRüdiger Schernthaner
- Gundula EdelhauserGEGundula Edelhauser
- Stefan PuchnerSPStefan Puchner
- Johannes LammerJLJohannes Lammer
- Martin A. FunovicsMFMartin A. Funovics
- 1 November 2007
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 189 (5) , 1238-1242
Abstract
OBJECTIVE. The purpose of this study was to compare CT angiography (CTA) and MR angiography (MRA) for the detectability of 75% and 95% stenoses in phantoms using six different stents.MATERIALS AND METHODS. Six different stents (Expander, Hemobahn, SelfX, Smart, Symphony, and Wallstent) were inserted into tubes filled with contrast agent (ioversol or gadoteric acid). To mimic stenoses of 75% and 95% of the patent lumen, 8-mm-diameter nylon cylinders were bored in the central axis (2 mm and 4 mm, respectively) and placed into the stent lumen. Intensity profiles across stenoses on 2-mm coronal reformatted sections of CTA or MRA were compared, and the detectability of the residual lumen was assessed using a subjective score.RESULTS. CTA showed relative in-stent signal attenuation for the in-stent stenoses of the tested stents ranging from 75% to 100% of the signal intensity of the control. SelfX and Symphony showed further shading of the residual lumen due to beam-hardening artifacts. Overestimation of stenos...Keywords
This publication has 25 references indexed in Scilit:
- Diagnostic Accuracy of Time-Resolved 2D Projection MR Angiography for Symptomatic Infrapopliteal Arterial Occlusive DiseaseAmerican Journal of Roentgenology, 2005
- Contrast-Enhanced MR Angiography at 1.5 T After Implantation of Platinum Stents: In Vitro and In Vivo Comparison with Conventional Stent DesignsAmerican Journal of Roentgenology, 2005
- Coronary Artery Stent Patency Assessed with In-Stent Contrast Enhancement Measured at Multi–Detector Row CT Angiography: Initial ExperienceRadiology, 2004
- Whole-Body 3D MR Angiography of Patients with Peripheral Arterial Occlusive DiseaseAmerican Journal of Roentgenology, 2004
- MRA Versus DSA in the Assessment of Occlusive Disease in the Aortic Arch Vessels:Accuracy in Detecting the Severity, Number, and Length of StenosesJournal of Endovascular Therapy, 2004
- Revealing In-Stent Stenoses of the Iliac Arteries: Comparison of Multidetector CT with MR Angiography and Digital Radiographic Angiography in a Phantom ModelAmerican Journal of Roentgenology, 2002
- Predictors of Long-Term Results After Treatment of Iliac Artery Obliteration by Transluminal Angioplasty and Stent DeploymentCardioVascular and Interventional Radiology, 2002
- MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysmsEuropean Radiology, 2002
- MRI contrast media – new developments and trends CTA vs. MRAEuropean Radiology, 1997
- Renal Handling and Physiologic Effects of the Paramagnetic Contrast Medium Gd-DOTAInvestigative Radiology, 1990